Simultaneous determination of buprenorphine and norbuprenorphine in serum by high-performance liquid chromatography-electrospray ionization-mass spectrometry.
نویسندگان
چکیده
Buprenorphine is a strong narcotic analgesic. It is also used in the substitution therapy for opium alkaloid addicts. The aim of this paper was to develop and validate a highly sensitive high-performance liquid chromatography-electrospray ionization-mass spectrometry method for simultaneous determination of buprenorphine and norbuprenorphine in human serum. The developed methodology was then applied to real clinical cases in a clinical toxicology setting. Extraction of analytes has been done using solid-phase extraction. Chromatographic separation was achieved on a LiChroCART column with a Purospher RP-18e cartridge, and for detection an LCQ mass spectrometer with an ion trap analyzer was used. Quantitation of buprenorphine and norbuprenorphine was performed in a single ion monitoring mode (m/z 468 buprenorphine, m/z 414 for norbuprenorphine) in order to increase the sensitivity of the method. The standard curves for both compounds were linear over the range of 0.2-10 ng/mL (r2 > 0.995). The quantitation limit was 0.2 ng/mL for both analytes. The method was used for quantitation of both buprenorphine and norbuprenorphine in the serum of 15 patients undergoing the buprenorphine substitution therapy. Serum concentrations ranged between 0.36 and 4.60 ng/mL for buprenorphine and 0.21 and 2.50 ng/mL for norbuprenorphine, with buprenorphine single dosages from 0.8 to 6.0 mg.
منابع مشابه
A sensitive, simple and rapid HPLC–MS/MS method for simultaneous quantification of buprenorpine and its N-dealkylated metabolite norbuprenorphine in human plasma
A sensitive, simple and rapid high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed and fully validated for the simultaneous quantification of buprenorphine (BUP) and its N-dealkylated metabolite norbuprenorphine (NBUP) in 200 μL human plasma. Human plasma samples were prepared using liquid-liquid extraction, and then separated on a Shiseido MG C18 (5...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of analytical toxicology
دوره 29 4 شماره
صفحات -
تاریخ انتشار 2005