Evaluation of Input Current in the Critical Mode Boost PFC Converter for Distributed Power Systems*
نویسندگان
چکیده
This paper presents the analysis and evaluation of the input current in the critical mode single-phase boost power-factor-correction (PFC) converter. First, the switching-frequency ripple of the input current is derived and the differential-mode EM1 filters of the critical and continuous mode PFC rectifiers are calculated and compared. Next, the benefits and challenges of interleaving the critical mode PFC rectifiers are discussed. Finally, the low-frequency input current distortions are analyzed with respect to the switching-frequency limits of the critical mode boost PFC rectifier.
منابع مشابه
Implementation of Floating Output Interleaved Input DC-DC Boost Converter
This paper presents the analysin ,design and implementation of a high voltage ratio topology of DC-DC converter. The DC-DC converter has high voltage ratio with reduced input current, output voltage and output current ripple, and also reduces the voltage and current rating of power electronics components and compared with conventional boost converter. The voltage stress on the switches are red...
متن کاملA New Passive Snubber for Improvement of Efficiency in Soft Switched Boost PFC Converter for Battery Charging Systems
This paper proposes a new passive snubber for enhancing the power conversion efficiency on a single phase ac-dc power factor correction (PFC) converter based on boost topology for battery charging systems. Soft switching can be achieved in the proposed converter with the proposed auxillary passive snubber circuit which is added to the conventional boost PFC converter. The converter switch is pr...
متن کاملتحلیل و طراحی روش کنترل پیش بین برای یکسو کننده دارای اصلاح ضریب توان با مبدل ارتقاء یافتهء شپارد- تیلور
In this paper CCM/CVM operation and modeling of the improved Sheppard-Taylor based power factor correction (PFC) rectifier is presented and a predictive control strategy is introduced for this rectifier. Compared with conventional boost or buck–boost PFC’s, this topology allows a better current tracking at the AC side, with a relatively reduced voltage at the DC side. Consequently, ...
متن کاملGeneralized Average-current-mode Control of Single-phase Ac-dc Boost Converters with Power Factor Correction
The dissertation presents a generalized average-current-mode control technique (GACMC), which is an extension of the average-current-mode control (ACMC) for single-phase ac-dc boost converters with power factor correction (PFC). Traditional ACMC is generalized in a sense that it offers improved performance in the form of significant reduction of the current control loop bandwidth requirement fo...
متن کاملAn Innovative Approach to Achieving Single Stage PFC and Step-Down Conversion for Distributive Systems
In most modern PFC circuits, to lower the input current harmonics and improve the input power factor, designers have historically used a boost topology. The boost topology can operate in the Continuous Conduction Mode (CCM), Discontinuous Conduction Mode (DCM), or Critical Conduction Mode. Most PFC applications using the boost topology are designed to operate over the universal input AC voltage...
متن کامل