Online dosimetric evaluation of larynx SBRT: A pilot study to assess the necessity of adaptive replanning

نویسندگان

  • Weihua Mao
  • Timothy Rozario
  • Weiguo Lu
  • Xuejun Gu
  • Yulong Yan
  • Xun Jia
  • Baran Sumer
  • David L. Schwartz
چکیده

PURPOSE We have initiated a multi-institutional phase I trial of 5-fraction stereotactic body radiotherapy (SBRT) for Stage III-IVa laryngeal cancer. We conducted this pilot dosimetric study to confirm potential utility of online adaptive replanning to preserve treatment quality. METHODS We evaluated ten cases: five patients enrolled onto the current trial and five patients enrolled onto a separate phase I SBRT trial for early-stage glottic larynx cancer. Baseline SBRT treatment plans were generated per protocol. Daily cone-beam CT (CBCT) or diagnostic CT images were acquired prior to each treatment fraction. Simulation CT images and target volumes were deformably registered to daily volumetric images, the original SBRT plan was copied to the deformed images and contours, delivered dose distributions were re-calculated on the deformed CT images. All of these were performed on a commercial treatment planning system. In-house software was developed to propagate the delivered dose distribution back to reference CT images using the deformation information exported from the treatment planning system. Dosimetric differences were evaluated via dose-volume histograms. RESULTS We could evaluate dose within 10 minutes in all cases. Prescribed coverage to gross tumor volume (GTV) and clinical target volume (CTV) was uniformly preserved; however, intended prescription dose coverage of planning treatment volume (PTV) was lost in 53% of daily treatments (mean: 93.9%, range: 83.9-97.9%). Maximum bystander point dose limits to arytenoids, parotids, and spinal cord remained respected in all cases, although variances in carotid artery doses were observed in a minority of cases. CONCLUSIONS Although GTV and CTV SBRT dose coverage is preserved with in-room three-dimensional image guidance, PTV coverage can vary significantly from intended plans and dose to critical structures may exceed tolerances. Online adaptive treatment re-planning is potentially necessary and clinically applicable to fully preserve treatment quality. Confirmatory trial accrual and analysis remains ongoing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Defining the Optimal Time of Adaptive Replanning in Prostate Cancer Patients with Weight Change during Volumetric Arc Radiotherapy: A Dosimetric and Mathematical Analysis Using the Gamma Index

We evaluated the changes in the dose distribution of radiation during volumetric arc radiotherapy (VMAT), to determine the right time for adaptive replanning in prostate cancer patients with progressive weight (WT) changes. Five prostate cancer patients treated with VMAT were selected for dosimetric analysis. On the original computed tomography images, nine artificial body contours were created...

متن کامل

Impact of Adaptive Radiotherapy on Locally Advanced Head and Neck Cancer - A Dosimetric and Volumetric Study.

UNLABELLED Objective of the study is to evaluate volumetric and dosimetric alterations taking place during radiotherapy for locally advanced head and neck cancer (LAHNC) and to assess benefit of replanning in them. MATERIALS AND METHODS Thirty patients with LAHNC fulfilling the inclusion and exclusion criteria were enrolled in a prospective study. Planning scans were acquired both pre-treatme...

متن کامل

SU-E-T-579: Dosimetric Benefits of Online Adaptive Replanning for Post-Operative Radiation Therapy of Prostate Bed.

PURPOSE To demonstrate the dosimetric benefits of using an online adaptive replanning scheme to address interfractional variations in radiotherapy of prostate bed. METHODS We have previously developed an online adaptive replanning tool (RealART, Prowess Inc.) aiming to address interfractional variations including organ deformation and rotation. Using this tool, we analyzed a total of 102 dail...

متن کامل

Assessment of anatomical and dosimetric changes by a deformable registration method during the course of intensity-modulated radiotherapy for nasopharyngeal carcinoma

The aim of this study was to quantify the anatomic variations and the dosimetric effects accessed by a deformable registration method throughout the entire course of radiotherapy, and to evaluate the necessity of replanning for patients with nasopharyngeal carcinoma (NPC). Plan1(CT1) was based on the original CT, and Plan2(CT2) was generated from the midtreatment CT scan acquired after 25 fract...

متن کامل

Design, Implementation and Evaluation of Azmer Online Quiz Application Based on Technology Acceptance Model (TAM): A pilot study

Introduction: Acceptance and intention to use the mobile device in the  student evaluation is an interesting topic in education. Although there are significant studies of mobile learning acceptance and mobile-based assessment (MBA), there is little research on app design and driving factors that influence students' intention to use mobile technology for assessment purposes. The purpose of this ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017