The influence of preload and heart rate on Doppler echocardiographic indexes of left ventricular performance: comparison with invasive indexes in an experimental preparation.
نویسندگان
چکیده
We evaluated the ability of Doppler echocardiography to assess left ventricular performance in six open-chest dogs studied under various conditions. Intravenous infusions of nitroglycerin were used to vary preload, atrial pacing was used to control heart rate, and changes in inotropic state were induced by two different doses of dobutamine (5 and 10 micrograms/kg/min iv) and by administration of propranolol (1 mg/kg iv). Left ventricular anterior wall myocardial segment length was used as an index of preload. Maximum aortic blood flow, peak acceleration of aortic blood flow, and dP/dt were measured with an electromagnetic flow probe around the ascending aorta and a high-fidelity pressure transducer in the left ventricle. A continuous-wave Doppler transducer applied to the aortic arch was used to measure peak aortic blood velocity, mean acceleration, time to peak velocity, and the systolic velocity integral. The differences between mean values obtained under different inotropic conditions were significant at the p less than .01 level for peak velocity and at the p less than .05 level for mean acceleration. Within a given animal, Doppler measurements of peak velocity correlated very closely with maximum aortic flow (r = .96), maximum acceleration of aortic flow (r = .95), and with maximum dP/dt (r = .92). Mean acceleration measured by Doppler echocardiography also correlated very closely with conventional indexes, but was subject to greater interobserver variability. Doppler measurements of time to peak and the systolic velocity integral correlated less well with conventional hemodynamic indexes.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Comparison of Doppler flow Tei-indexes with pulmonary artery thermodilution measurement of cardiac output in an experimental porcine model.
The objective of our study was to compare Doppler echocardiography imaging with pulmonary artery thermodilution measurement during mechanical ventilation. Total 78 piglets (6 weeks old, average weight 24 kg, under general anesthesia) were divided into 4 groups under different cardiac loading conditions (at rest, with increased left ventricular afterload, with increased right ventricular preload...
متن کاملIs It Still Valid to Measure Ejection Fraction When There Are New Deformation Indexes to Evaluate Ventricular Function? Agonist
An echocardiographic study helps in the assessment of systolic and diastolic left ventricular function due to potential clinical implications over the treatment and the prognosis of different heart diseases. Systolic function depends on three factors: the left ventricular (LV) function, arterial coupling (ventriculoarterial coupling) and blood volume. In the particular case of the left ventricu...
متن کاملValidation of echocardiographic and Doppler indexes of left ventricular relaxation in adult hypertensive and normotensive rats.
This study was performed to validate echocardiographic and Doppler techniques for the assessment of left ventricular (LV) diastolic function in spontaneously hypertensive rats (SHR) and normotensive Wistar rats. In 11 Wistar rats and 20 SHR, we compared 51 sets of invasive and Doppler LV diastolic indexes. Noninvasive indexes of LV relaxation were related to the minimal rate of pressure decline...
متن کاملDoppler-Derived Myocardial Performance Index in Healthy Children in Shiraz
Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...
متن کاملNoninvasive Doppler-derived myocardial performance index in rats with myocardial infarction: validation and correlation by conductance catheter.
The rodent model of myocardial infarction (MI) is extensively used in heart failure studies. However, long-term follow-up of echocardiographic left ventricular (LV) function parameters such as the myocardial performance index (MPI) and its ratio with the fractional shortening (LVFS/MPI) has not been validated in conjunction with invasive indexes, such as those derived from the conductance cathe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 74 1 شماره
صفحات -
تاریخ انتشار 1986