Solid State Electronic Fault Current Limiter to Limit the Fault Current in Power System

نویسندگان

  • Vinod Gupta
  • U. C. Trivedi
  • N. J. Buch
چکیده

Increase in power generation capacity of electric power systems has lead to increase in the fault current level which can exceed the maximum designed short-circuit ratings of the switchgear. All the equipment therefore must have a short-circuit rating capable to withstand this level. Short-circuit currents contain extremely high energy and can damage electrical equipment. Typically, the circuit breakers open automatically in three to six cycles when a fault occurs. But circuit breakers, sometimes cannot handle the intense level of faults, as they are designed to handle designed faults current level so they fail to “break” and force a system to collapse. Advanced current interruption technology, utilizing high power Solid-State Fault Current Limiters (SSFCL) offers a viable solution to the transmission and distribution system problems caused by high system fault current. The SSFCL alleviates the short circuit condition in both downstream devices by limiting fault currents. To interrupt the current, SSFCL must rapidly insert an energy absorbing element (e.g. resistor) into the circuit to limit the fault current. A proper design of current limiting device will ensure that the fault current in the system is kept as low as possible in order to limit the surge current rating of the thyristor and also to minimize stresses on the power system network.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System

In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...

متن کامل

Influence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm

Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...

متن کامل

بهبود قابلیت گذر از خطای منابع تولید پراکنده مبتنی بر اینورتر با استفاده از محدود کننده‌ی جریان خطا

By increasing the penetration level of the inverter-based distributed generations (IBDGs) in power system, their fault ride through capability has become one of the essential issues of the new grid codes. This paper proposes a novel method to limit inverter fault currents which are used in DGs. To achieve FRT, interface-inverter operates as a controlled voltage source during normal operation as...

متن کامل

Optimal Placement and Sizing of Fault Current Limiter in a Real Network: a Case Study (TECHNICAL NOTE)

In this paper, the effect of number and fault current limiter(FCL) location has been investigated in order to have maximum reduction of short circuit current level in all buses in a real network. To do so, the faulty buses were identified in terms of short circuit current level by computing short circuits on the desired network. Then, while the fault current limit was modeled, its optimal locat...

متن کامل

A New Method to Enhance the Low Voltage Ride Through Capability of Doubly Fed Induction Generator Using Resistive Type Superconducting Fault Current Limiter

In the event of voltage sag at the nearing of a wind park, severe currents may pass through the power electronic devices of the Doubly Fed Induction Generators (DFIGs). Hence, according to the Low Voltage Ride Through (LVRT) requirements, the wind parks are allowed to disconnect from the network after a certain time. Therefore, to avoid such actions, the LVRT requirement of wind parks is consid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010