Diagnostic image quality of hysterosalpingography: ionic versus non ionic water soluble iodinated contrast media

نویسندگان

  • H Mohd Nor
  • KJ Jayapragasam
  • BJJ Abdullah
چکیده

OBJECTIVE To compare the diagnostic image quality between three different water soluble iodinated contrast media in hysterosalpingography (HSG). MATERIAL AND METHOD In a prospective randomised study of 204 patients, the diagnostic quality of images obtained after hysterosalpingography were evaluated using Iopramide (106 patients) and Ioxaglate (98 patients). 114 patients who had undergone HSG examination using Iodamide were analysed retrospectively. Image quality was assessed by three radiologists independently based on an objective set of criteria. The obtained results were statistically analysed using Kruskal-Wallis and Mann-Whitney U test. RESULTS Visualisation of fimbrial rugae was significantly better with Iopramide and Ioxaglate than Iodamide. All contrast media provided acceptable diagnostic image quality with regard to uterine, fallopian tubes outline and peritoneal spill. Uterine opacification was noted to be too dense in all three contrast media and not optimal for the assessment of intrauterine pathology. Higher incidence of contrast intravasation was noted in the Iodamide group. Similarly, the numbers of patients diagnosed with bilateral blocked fallopian tubes were also higher in the Iodamide group. CONCLUSION HSG using low osmolar contrast media (Iopramide and Ioxaglate) demonstrated diagnostic image qualities similar to HSG using conventional high osmolar contrast media (Iodamide). However, all three contrast media were found to be too dense for the detection of intrauterine pathology. Better visualisation of the fimbrial outline using Ioxaglate and Iopramide were attributed to their low contrast viscosity. The increased incidence of contrast media intravasation and bilateral tubal blockage using Iodamide are probably related to the high viscosity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost–effectiveness of iodinated contrast media for CT scanning in Spain: a decision-based analysis

Background Iodinated contrast media (CM) are among the most commonly used radiocontrast agents in radiographic examinations or in MRI studies. The clinical development of non-ionic low-osmolar or iso-osmolar iodinated CM has improved both image quality and safety of radioimaging studies. Nevertheless, CM-induced adverse reactions continue to be a public health problem; they are unpredictable an...

متن کامل

The molecular mechanism of contrast-induced nephropathy (CIN) and its link to in vitro studies on iodinated contrast media (CM)

Iodinated contrast media (iodinated CM) have increased ability to absorb x-rays and to visualize structures that normally are impossible to observe in a radiological examination. The use of iodinated CM may destory renal function, commonly known as contrast-induced nephropathy (CIN), which can result in acute renal failure (ARF). This review article mainly focuses on the following areas: (1) cl...

متن کامل

Induction of DNA damage, apoptosis and micronuclei in peripheral blood lymphocytes following injection of contrast media in patients with abdominal CT scan

Background: Medical diagnostic procedures such as X-ray and computed Tomography (CT) scan account for considerable percent of patient's exposure to ionizing radiation. The exposure of cells to Ionization radiation results in induction of DNA damage and chromosomal aberrations. Contrast media (CM) are widely used in diagnostic radiology and CT scan. The aim of this study was to study adverse gen...

متن کامل

The prevention of anaphylactoid reactions to iodinated radiological contrast media: a systematic review

BACKGROUND Anaphylactoid reactions to iodinated contrast media are relatively common and potentially life threatening. Opinion is divided as to the utility of medications for preventing these reactions. We performed a systematic review to assess regimes for the prevention of anaphylactoid reactions to iodinated contrast media. METHODS Searches for studies were conducted in the Medline, EMBASE...

متن کامل

Highly-iodinated fullerene as a contrast agent for X-ray imaging.

The first fullerene-based X-ray contrast agent (CA) has been designed, synthesized, and characterized. The new CA is an externally functionalized derivative of C60 that is conceptually based on contemporary X-ray CA, all of which use iodine as the X-ray attenuating vehicle and are based on the 2,4,6-triiodinated-benzene-ring substructure. Using a modified Bingel-type reaction, a single addend c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2009