Skull Reconstruction with Custom Made Three-Dimensional Titanium Implant

نویسندگان

  • Hyung Rok Cho
  • Tae Suk Roh
  • Kyu Won Shim
  • Yong Oock Kim
  • Dae Hyun Lew
  • In Sik Yun
چکیده

BACKGROUND Source material used to fill calvarial defects includes autologous bones and synthetic alternatives. While autologous bone is preferable to synthetic material, autologous reconstruction is not always feasible due to defect size, unacceptable donor-site morbidity, and other issues. Today, advanced three-dimensional (3D) printing techniques allow for fabrication of titanium implants customized to the exact need of individual patients with calvarial defects. In this report, we present three cases of calvarial reconstructions using 3D-printed porous titanium implants. METHODS From 2013 through 2014, three calvarial defects were repaired using custommade 3D porous titanium implants. The defects were due either to traumatic subdural hematoma or to meningioma and were located in parieto-occipital, fronto-temporo-parietal, and parieto-temporal areas. The implants were prepared using individual 3D computed tomography (CT) data, Mimics software, and an electron beam melting machine. For each patient, several designs of the implant were evaluated against 3D-printed skull models. All three cases had a custom-made 3D porous titanium implant laid on the defect and rigid fixation was done with 8 mm screws. RESULTS The custom-made 3D implants fit each patient's skull defect precisely without any dead space. The operative site healed without any specific complications. Postoperative CTs revealed the implants to be in correct position. CONCLUSION An autologous graft is not a feasible option in the reconstruction of large calvarial defects. Ideally, synthetic materials for calvarial reconstruction should be easily applicable, durable, and strong. In these aspects, a 3D titanium implant can be an optimal source material in calvarial reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prefabricated Patient-Matched Cranial Implants for Reconstruction of Large Skull Defects

Cranial defects can be caused by injury, infection, or tumor invasion. Large defects should be reconstructed to protect the brain and normalize the cerebral hemodynamics. The conventional method is to cover the defect with bone cement. Custom-made implants designed for the individual patient are now available. We report our experience with one such product in patients with large cranial defects...

متن کامل

Three-Dimensional Custom-Made Titanium Ribs for Reconstruction of a Large Chest Wall Defect

Reconstruction of large chest wall defects always demand surgeons of having lots of means available (both materials and resourceful) to apply a cover to chest wall defects which can range from a few centimeters to the lack of a few entire ribs. In this study, we present the case of a teenager who suffered from a complete resection of three ribs because of Ewing sarcoma dependent on the sixth ri...

متن کامل

The use of 3D printing technology in human defect reconstruction-a review of cases study

In this paper, we report the benefit of Computer Tomography (CT), reverse engineering (RE) and rapid prototyping (RP) in individual implant production for maxillofacial surgery. The design and fabrication processes includes: a) processing medical image data of a patient’s pathologically defective area having a symmetrical part to construct a three-dimensional (3D) digital model; b) forming an i...

متن کامل

Rapid prototyping assisted surgery planning and custom implant design

Purpose – This paper aims to describe computer-aided design and rapid prototyping (RP) systems for the preoperative planning and fabrication of custom-made implant. Design/methodology/approach – A patient with mandible defect underwent reconstruction using custom-made implant. 3D models of the patient’s skull are generated based on computed tomography image data. After evaluation of the 3D reco...

متن کامل

Histological assessment of porous custom-made hydroxyapatite implants 6 months and 2.5 years after cranioplasty

BACKGROUND In cranial reconstruction, the features of artificial bone differ. Custom-made porous hydroxyapatite (HAp) implants for cranioplasty have been used all over the world because of their good cosmetic, biocompatibility, and osteoconductive properties. Surgical techniques were analyzed, and histological assessment of new bone formation in the hydroxyapatite was performed. METHODS Over ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015