Two-year-plus follow-up of a paclitaxel-eluting stent in de novo coronary narrowings (TAXUS I).
نویسندگان
چکیده
Early results with polymer-based paclitaxel-eluting stents have shown significant improvements in the clinical and angiographic parameters of restenosis, as well as excellent safety outcomes. However, the duration of these beneficial effects is unknown. Therefore, the clinical outcomes of the TAXUS I study population were evaluated at 2- and 3-year follow-up. In TAXUS I, 61 patients with single, focal coronary lesions were randomly assigned to receive either a paclitaxel-eluting TAXUS stent (n = 31) or a bare metal control stent (n = 30). Low rates of composite major adverse cardiac events (MACEs) reported at 1-year follow-up (3.2% TAXUS vs 10.0% control) were maintained at 2 and 3 years, with no additional MACEs in either treatment group 1 year after implantation. The single target vessel revascularization in the TAXUS group was remote from the target lesion in contrast to 3 target lesion revascularizations in the control group.
منابع مشابه
The "final voyage" of the Endeavor stent.
The “final” 5-year outcomes of combined trials with the Endeavor zotarolimus-eluting stent (E-ZES) by Kandzari et al. (1), published in this issue of JACC: Cardiovascular Interventions, might be considered a companion to the Kirtane et al. (2) publication in the issue last month of JACC: Cardiovascular Interventions, which reported on the “final” 5-year follow-up of the ENDEAVOR IV (A Randomize...
متن کاملOne-Year Clinical Results With the Slow-Release, Polymer-Based, Paclitaxel-Eluting TAXUS Stent
Background—The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. Methods and Results—In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were pr...
متن کاملThe "final" 5-year follow-up from the ENDEAVOR IV trial comparing a zotarolimus-eluting stent with a paclitaxel-eluting stent.
OBJECTIVES This study sought to report the final 5-year outcomes of the ENDEAVOR IV (A Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) trial comparing the Endeavor zotarolimus-eluting stent (E-ZES) (Medtronic, Santa Rosa, California) with the T...
متن کاملOne-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent in patients with diabetes mellitus.
Background—The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. Methods and Results—In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were pr...
متن کاملIn-Stent Restenosis Treated With Stent-Based Delivery of Paclitaxel Incorporated in a Slow-Release Polymer Formulation
Background—The first clinical study of paclitaxel-eluting stent for de novo lesions showed promising results. We performed the TAXUS III trial to evaluate the feasibility and safety of paclitaxel-eluting stent for the treatment of in-stent restenosis (ISR). Methods and Results—The TAXUS III trial was a single-arm, 2-center study that enrolled 28 patients with ISR meeting the criteria of lesion ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of cardiology
دوره 96 1 شماره
صفحات -
تاریخ انتشار 2005