Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma.

نویسندگان

  • Felipe A Medeiros
  • Linda M Zangwill
  • Christopher Bowd
  • Pamela A Sample
  • Robert N Weinreb
چکیده

PURPOSE To evaluate the influence of disease severity and optic disc size on the diagnostic accuracy of three imaging technologies for structural assessment in glaucoma: confocal scanning laser ophthalmoscopy, scanning laser polarimetry, and optical coherence tomography. METHODS One hundred five patients with glaucoma and 61 normal subjects were recruited from the Diagnostic Innovations in Glaucoma Study (DIGS). All individuals underwent imaging with the GDx Variable Corneal and Lens Compensator (VCC; Carl Zeiss Meditec, Inc., Dublin, CA), the Heidelberg Retina Tomograph II (HRT II; Heidelberg Engineering, GmbH, Dossenheim, Germany), and the Stratus OCT (Stratus OCT; Carl-Zeiss Meditec, Inc.) within a 6-month period. Severity of disease was based on the AGIS (Advanced Glaucoma Intervention Study) visual field score. To evaluate the influence of severity of glaucoma and optic disc size on the diagnostic accuracy of the imaging instruments, the sensitivities of the tests were fitted as a function of the AGIS score and disc area, by using logistic marginal regression models. RESULTS The severity of visual field loss had a significant influence on the sensitivity of all imaging instruments. More severe disease was associated with increased sensitivity. This influence was similar among the three instruments. With regard to optic disc area, larger optic discs were associated with decreased sensitivity for the Stratus OCT parameter Average Thickness and the GDx VCC parameter Nerve Fiber Indicator, whereas small optic discs were associated with increased sensitivity. For the HRT II parameter Moorfields regression analysis classification, an inverse effect was observed. CONCLUSION The diagnostic performances of the GDx VCC, HRT II, and Stratus OCT were significantly influenced by the severity of the disease and optic disc size. These covariates should be taken into account when comparing the performances of these tests for glaucoma diagnosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of disease severity and optic disc size on diagnostic accuracy of RTVue spectral domain optical coherence tomograph in glaucoma.

PURPOSE To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. METHODS 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in...

متن کامل

The effects of race, optic disc area, age, and disease severity on the diagnostic performance of spectral-domain optical coherence tomography.

PURPOSE To evaluate the effect of race (African or European descent), age, disc area, and severity of disease on the diagnostic ability of spectral-domain optical coherence tomography (SDOCT) imaging of the optic nerve, macula, and retinal nerve fiber layer (RNFL) in the detection of glaucomatous injury. METHODS In this cross-sectional observational study, data from SDOCT images of 312 eyes o...

متن کامل

Evaluation of Retinal Optic Disc Segmentation in Patients with Glaucoma and Comparison with Other Methods of Medical Image Processing

Introduction: Glaucoma is the most common cause of blindness in some countries. In the meantime, the field of retinal image processing has been proposed in order to provide automatic systems for disease diagnosis. Among the methods of medical image processing, image segmentation is a process of identification and change in the display of an image. The objective of this study was to use t...

متن کامل

Evaluation of Retinal Optic Disc Segmentation in Patients with Glaucoma and Comparison with Other Methods of Medical Image Processing

Introduction: Glaucoma is the most common cause of blindness in some countries. In the meantime, the field of retinal image processing has been proposed in order to provide automatic systems for disease diagnosis. Among the methods of medical image processing, image segmentation is a process of identification and change in the display of an image. The objective of this study was to use t...

متن کامل

Effect of disease severity on the performance of Cirrus spectral-domain OCT for glaucoma diagnosis.

PURPOSE To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2006