Quality assessment of ozone total column amounts as monitored by ground-based solar absorption spectrometry in the near infrared (> 3000 cm−1)

نویسندگان

  • O. E. García
  • M. Schneider
  • F. Hase
  • T. Blumenstock
  • E. Sepúlveda
چکیده

This study examines the possibility of groundbased remote-sensing ozone total column amounts (OTC) from spectral signatures at 3040 and 4030 cm−1. These spectral regions are routinely measured by the NDACC (Network for the Detection of Atmospheric Composition Change) ground-based FTIR (Fourier transform infraRed) experiments. In addition, they are potentially detectable by the TCCON (Total Carbon Column Observing Network) FTIR instruments. The ozone retrieval strategy presented here estimates the OTC from NDACC FTIR high-resolution spectra with a theoretical precision of about 2 and 5 % in the 3040 and 4030 cm−1 regions, respectively. Empirically, these OTC products are validated by inter-comparison to FTIR OTC reference retrievals in the 1000 cm−1 spectral region (standard reference for NDACC ozone products), using an 8-year FTIR time series (2005–2012) taken at the subtropical ozone supersite of the Izaña Atmospheric Observatory (Tenerife, Spain). Associated with the weaker ozone signatures at the higher wave number regions, the 3040 and 4030 cm−1 retrievals show lower vertical sensitivity than the 1000 cm−1 retrievals. Nevertheless, we observe that the rather consistent variations are detected: the variances of the 3040 cm−1 and the 4030 cm−1 retrievals agree within 90 and 75 %, respectively, with the variance of the 1000 cm−1 standard retrieval. Furthermore, all three retrievals show very similar annual cycles. However, we observe a large systematic difference of about 7 % between the OTC obtained at 1000 and 3040 cm−1, indicating a significant inconsistency between the spectroscopic ozone parameters (HITRAN, 2012) of both regions. Between the 1000 cm and the 4030 cm−1 retrieval the systematic difference is only 2–3 %. Finally, the longterm stability of the OTC retrievals has also been examined, observing that both near-infrared retrievals can monitor the long-term OTC evolution, consistent with the 1000 cm−1 reference data. These findings demonstrate that recording the solar absorption spectra in the 3000 cm−1 spectral region at high spectral resolution (about 0.005 cm−1) might be useful for TCCON sites. Hence, both NDACC and TCCON groundbased FTIR experiments might contribute to global ozone databases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical Note: Recipe for monitoring of total ozone with a precision of around 1 DU applying mid-infrared solar absorption spectra

Mid-infrared solar absorption spectra recorded by a state-of-the-art ground-based FTIR system have the potential to provide precise total O3 amounts. The currently bestperforming retrieval approaches use a combination of small and broad spectral O3 windows between 780 and 1015 cm−1. We show that for these approaches the uncertainties of the temperature profile are by far the major error sources...

متن کامل

Recipe for continuous monitoring of total ozone with a precision of around 1DU applying mid-infrared solar absorption spectra

Introduction Conclusions References Tables Figures ◭ ◮ ◭ ◮ Back Close Full Screen / Esc Abstract Introduction Conclusions References Tables Figures ◭ ◮ ◭ ◮ Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion EGU Abstract Mid-infrared solar absorption spectra recorded by a state-of-the-art ground-based FTIR system have the potential to provide precise total O 3 amounts. ...

متن کامل

Validation of Ozone Monitoring Instrument total ozone column measurements using Brewer and Dobson spectrophotometer ground- based observations

[1] In this paper we present validation results of the total ozone column data products of the Ozone Monitoring Instrument (OMI) on board the NASA EOS-AURA satellite through comparisons with ground-based observations by Dobson and Brewer spectrophotometer instruments. Quality-controlled and archived total ozone column data from these ground-based instruments located at stations worldwide have b...

متن کامل

GOME level 1-to-2 data processor version 3.0: a major upgrade of the GOME/ERS-2 total ozone retrieval algorithm.

The global ozone monitoring experiment (GOME) was launched in April 1995, and the GOME data processor (GDP) retrieval algorithm has processed operational total ozone amounts since July 1995. GDP level 1-to-2 is based on the two-step differential optical absorption spectroscopy (DOAS) approach, involving slant column fitting followed by air mass factor (AMF) conversions to vertical column amount...

متن کامل

Heavy Ozone Enrichments from ATMOS Infrared Solar Spectra

Vertical enrichment profiles of stratospheric 160160180 and 160•80160 (hereafter referred to as 6680 3 and 6860 3 respectively) have been derived from space-based solar occultation spectra recorded at 0.01 cm -I resolution by the ATMOS (Atmospheric Trace MOlecule Spectroscopy) Fouriertransform infrared (FTIR) spectrometer. The observations, made during the Spacelab 3 and ATLAS-l, -2, and -3 shu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014