Comparison of polyethylene wear in anatomical and reversed shoulder prostheses.
نویسندگان
چکیده
Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movement and joint stability were achieved by EMG-controlled activation of the muscles. A non-constant wear factor was considered. Simulated activities of daily living were estimated from in vivo recorded data. After one year of use, the volumetric wear was 8.4 mm(3) for the anatomical prosthesis, but 44.6 mm(3) for the reversed version. For the anatomical prosthesis the predictions for contact pressure and wear were consistent with biomechanical and clinical data. The abrasive wear of the polyethylene in reversed prostheses should not be underestimated, and further analysis, both experimental and clinical, is required.
منابع مشابه
Polyethylene Wear in Anatomic and Reversed Shoulder Prostheses
INTRODUCTION: Polyethylene wear is a recurrent problem in joint arthroplasty. In addition to permanent deformation or complete destruction of the component, small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. In anatomic total shoulder arthroplast...
متن کاملSimulated joint and muscle forces in reversed and anatomic shoulder prostheses.
Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active ...
متن کاملLong-term results and patient satisfaction after shoulder resurfacing.
BACKGROUND Shoulder resurfacing has regained popularity in recent years. This report presents the long-term (>20 years) results of this procedure with regard to patient satisfaction and implant survival. MATERIALS AND METHODS We followed up 61 patients who underwent shoulder resurfacing procedures (74 shoulders) for a minimum of 20 years or until death (7 additional patients were lost to foll...
متن کاملDegree of the Polyethylene Component Wear – a Predictive Factor for the Outcome of Total Hip Arthroplasty
In patients suffering of osteoarthritis of the hip (a degenerative condition of the hip that finally leads to anatomical and functional impairment of the joint), the only efficient treatment in advanced stages of the disease is the surgical replacement of the joint with a total hip prosthesis. Unfortunately, despite improving the composition of the materials from which these prostheses are made...
متن کاملWear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners
The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display-using a 3D optical scanner-wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 91 7 شماره
صفحات -
تاریخ انتشار 2009