Detection biomarkers of lung cancer using mini-GC-PID system integrated with micro GC column and micro pre-concentrator
نویسندگان
چکیده
The survival rate of lung cancer can be significantly improved by monitoring biomarkers in exhaled air that indicate diseases in early stage, so it is very important to develop micro analytical systems which can offer a fast, on-site, real-time detecting biomarkers in exhaled air. In this paper, a mini-gas chromatography (GC)-photo-ionization detector (PID) system integrated with a micro GC column and a micro pre-concentrator was developed for forming an inexpensive, fast, and non-invasive diagnostic tool for lung cancer. This system has very strong concentrate ability owing to its integrated micro pre-concentrator, which make the detection of trace components in exhaled air very easy. In addition, the integrated micro GC column can separate complex mixtures, which overcome low resolution and poor anti-interference ability of other instruments. The results indicated that the mini-GC-PID system can effectively separate and detect the biomarkers at parts-per-billion (ppb) level.
منابع مشابه
Bacterial and tissue biomarkers of gastric cancer: new findings and future perspectives: review article
Gastric cancer (GC) is the second leading cause of cancer-related deaths worldwide. It has been proposed that the specific genotypes of Helicobacter pylori (H. pylori) are the causative agents in the development of gastroduodenal diseases, such as chronic atrophic gastritis, peptic ulcerations, and GC. However, disease progression to GC occurs in only a small proportion of infected patients. Re...
متن کاملSeparation and screening of short-chain chlorinated paraffins in environmental samples using comprehensive two-dimensional gas chromatography with micro electron capture detection.
Short-chain chlorinated paraffins (SCCPs) are highly complex technical mixtures with thousands of isomers and numerous homologs. They are classified as priority candidate persistent organic pollutants under the Stockholm Convention for their persistence, bioaccumulation, and toxicity. Analyzing SCCPs is challenging because of the complexity of the mixtures. Chromatograms of SCCPs acquired using...
متن کاملA monolithically fabricated gas chromatography separation column with an integrated high sensitivity thermal conductivity detector
The monolithic integration of a high sensitivity detector with a gas chromatography (GC) separation column creates many potential advantages over the discrete components of a traditional chromatography system. In miniaturized high-speed GC systems, component interconnections can cause crucial errors and loss of fidelity during detection and analysis. A monolithically integrated device would eli...
متن کاملMini/Micro-Grid Adaptive Voltage and Frequency Stability Enhancement Using Q-learning Mechanism
This paper develops an adaptive control method for controlling frequency and voltage of an islanded mini/micro grid (M/µG) using reinforcement learning method. Reinforcement learning (RL) is one of the branches of the machine learning, which is the main solution method of Markov decision process (MDPs). Among the several solution methods of RL, the Q-learning method is used for solving RL in th...
متن کاملFast and Efficient Volatiles Analysis by Purge and Trap Gc/ms
Recent changes in environmental regulatory paradigms, such as EPA’s performance-based measurement systems (PBMS), are lowering method compliance barriers for laboratories working under the Resource Conservation and Recovery Act (RCRA). One of the stated goals of PBMS is to educate the regulators and the regulated community on the inherent and intended flexibility of SW-846 methods. Operating un...
متن کامل