Evaluation of individually ventilated cage systems for laboratory rodents: cage environment and animal health aspects.

نویسندگان

  • A U Höglund
  • A Renström
چکیده

The use of individually ventilated cage (IVC) systems has become an attractive housing regime of laboratory rodents. The benefits of IVC systems are, reportedly, a high degree of containment combined with relative ease of handling, and a high degree of protection from allergenes. In the present study we tested whether two IVC systems (BioZone VentiRack, IVC1 and Techniplast SealSafe, IVC2S), in which we held mature male NMRI mice, were constructed to maintain a constant differential pressure, positive or negative, during a prolonged period of time. We also measured ammonia (NH3) concentrations after about 2 weeks of use, and CO2 build-up during a 60 min simulated power failure situation. In addition, animal weight development and bite-wound frequency were recorded (Renström et al. 2000). From the present study it is concluded that the IVC1 air handling system provides a more uniform and balanced differential pressure than the IVC2S. Both systems effectively scavenge NH3 when bedding material is not soaked by urine. Although the IVCs are dependent on the continual function of the fans to work properly, it seems unlikely that CO2 concentrations increase to hazardous levels, as a result of a one hour power failure, with the type of cages used in this study. Differences in weight development and bite-wound occurrence were noted between the two IVC systems. Causes for these differences could not be established and need more investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microbiota composition of simultaneously colonized mice housed under either a gnotobiotic isolator or individually ventilated cage regime

Germ-free rodents colonized with microbiotas of interest are used for host-microbiota investigations and for testing microbiota-targeted therapeutic candidates. Traditionally, isolators are used for housing such gnotobiotic rodents due to optimal protection from the environment, but research groups focused on the microbiome are increasingly combining or substituting isolator housing with indivi...

متن کامل

Evaluation of cage micro-environment of mice housed on various types of bedding materials.

A variety of environmental factors can affect the outcomes of studies using laboratory rodents. One such factor is bedding. Several new bedding materials and processing methods have been introduced to the market in recent years, but there are few reports of their performance. In the studies reported here, we have assessed the cage micro-environment (in-cage ammonia levels, temperature, and humi...

متن کامل

The effect of two different Individually Ventilated Cage systems on anxiety-related behaviour and welfare in two strains of laboratory mouse

The environment in which a laboratory animal is housed can significantly influence its behaviour and welfare, acting as a potential confounding factor for those studies in which it is utilised. This study investigated the impact of two Individually Ventilated Cage (IVC) housing systems on anxiety-related behaviour and welfare indicators in two common strains of laboratory mice. Subjects were ju...

متن کامل

The future of lab animal facilities in Brazil

The evolution of rodents cages marked major improvements of animal and staff protection. Aspects pertaining to animal welfare and the need for higher flexibility in space used led to the development and success of Individually Ventilated Cages (IVCs), extensively used in modern animal facilities. The concept of “room at cage level” along with the latest innovations in IVCs will be reviewed. The...

متن کامل

The impact of cage ventilation on rats housed in IVC systems.

Today the use of individually ventilated cage systems (IVC systems) is common, especially for housing transgenic rodents. Typically, in each cage a ventilation rate of 40 to 50 air changes per hour is applied, but in some systems even up to 120 air changes per hour is applied. To reach this rate, the air is blown into the cage at a relatively high speed. However, at the animal's level most syst...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Laboratory animals

دوره 35 1  شماره 

صفحات  -

تاریخ انتشار 2001