Pressure-broadening coefficients and line strengths of H2O near 1.39 mm: application to the in situ sensing of the middle atmosphere with balloonborne diode lasers
نویسندگان
چکیده
Since 1998, we have developed two balloonborne diode laser spectrometers, SDLA and micro-SDLA, to yield in situ concentration data of H2O in the middle atmosphere by absorption spectroscopy in the 1.39mm spectral range. In this paper, we revisit the molecular parameters, line intensities and pressurebroadening coefficients, for several lines of the n1+n3 and 2n1 bands, which are useful for the monitoring of atmospheric H2O. The new values are thoroughly compared to existing molecular database and previous determinations. Calculations are performed to yield the pressure-effect coefficients: the theoretical model is described and the ab initio predictions are compared to laboratory measurements achieved with a laser diode spectrometer. The improvement in the H2O monitoring obtained with the new set of molecular data is evaluated directly from vertical H2O concentration profiles. r 2004 Elsevier Ltd. All rights reserved.
منابع مشابه
طیف سنج لیزر اختلاف فرکانسMIR برای آشکارسازی CO در شعله
Two continuous-wave (cw) single mode diode-lasers (Toshiba TOLD 9150 and Sharp LT024MDO) are applied as pump and signal sources to obtain difference-frequency generation (DFG) in the mid-infrared (MIR) region by using an AgGaS2 crystal with a length of 30 mm for 90° type I phase-matching. Tuneable MIR laser radiation around 5 µm is obtained with an output power in the order of hundred nW while...
متن کاملOPTIMAL NOZZLE SHAPES OF CO2-N2-H2O GASDYNAMIC LASERS
In an axisymmetric CO2-N2-H2O gas dynamic laser, let ? denote the intersection of the vertical plane of symmetry with the upper part of the (supersonic) nozzle. To obtain a maximal small signal gain, some authors have tested several families of curves for ?. To find the most general solution for ?, an application of Pontryagin’s principle led to the conjuncture that the optimal ? must consist o...
متن کاملHigh-resolution absorption measurements by use of two-tone frequency-modulation spectroscopy with diode lasers.
The capability of two-tone frequency-modulation spectroscopy (TTFMS) in deriving spectral line-shape information was investigated. Two oxygen A-band transitions at 760 nm were selected, and the Voigt profile and two different collisionally narrowed line profiles were employed in their analysis. By means of a least-squares fitting procedure, we obtained accurate information regarding transition ...
متن کاملAmmonia Monitoring Near 1.5 mum with Diode-Laser Absorption Sensors.
We investigated ammonia spectroscopy near 1.5 mum to select transitions appropriate for trace ammonia detection in air-quality and combustion emissions-monitoring applications using diode lasers. Six ammonia features were selected for these trace-gas detection applications based on their transition strengths and isolation from interfering species. The strengths, positions, and lower-state energ...
متن کاملComparison the Effect of 810 nm and 940 nm Diode Lasers on Solobacterium Moorei in Vitro
Background and aim: Given the role of Solobacterium moorei in bacteremia, septicemia, oral infections, halitosis, and periodontal diseases and previous research defects considering the important role of laser in comparison with the application of antimicrobial agents, the purpose of this research was to compare the effect of 810nm and 940nm lasers on Solobacterium moorei in vitro situation. Mat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004