Less smoke and minimal tissue carbonization using a thulium laser for laparoscopic partial nephrectomy without hilar clamping in a porcine model.

نویسندگان

  • Matthew H Bui
  • Alberto Breda
  • Dorina Gui
  • Johnathan Said
  • Peter Schulam
چکیده

PURPOSE We evaluated the utility of a thulium laser and a novel implementation of its use for laparoscopic partial nephrectomy to achieve precise, smokeless, and hemostatic dissection without hilar clamping and with minimal charring in a porcine model. MATERIALS AND METHODS Laparoscopic transperitoneal lower-pole partial nephrectomy was performed in five Yorkshire farm pigs without clamping of the renal hilum. All animals were kept alive for 1 week. Using a 365-mum laser fiber, a 30 W thulium laser was used to produce full-thickness cortical excisions of the lower-pole renal cortex. The laser fiber was delivered through the working channel of a 16F flexible cystoscope inserted through a 10-mm laparoscopic port. The laser incision was directed by manual deflection of the cystoscope along with low-pressure saline irrigation through the cystoscope. RESULTS Laparoscopic partial nephrectomy was completed in all cases without perioperative complications and with an estimated blood loss of <50 mL. The thulium laser was able to cut tissue and simultaneously to coagulate vessels as large as 1.6 mm. The flexible cystoscope with concurrent saline irrigation permitted precise laser control for dissection with minimal tissue charring and no smoke to obscure visibility. At 1 week, the cut edge of the tissue showed minimal necrosis with preservation of histologic architecture. CONCLUSIONS Laparoscopic partial nephrectomy with the thulium laser provides precise dissection and hemostasis without hilar clamping. Minimal tissue charring and no smoke generation improve visibility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CASE REPORTS : Zero Ischemia Robotic Laser Partial Nephrectomy : Use of the Thulium laser in Renal Cell Carcinoma

Objective To describe use of a robotic-assisted laparoscopic partial nephrectomy technique utilizing the thulium laser for tissue welding without clamping the hilar vessels. Materials and Methods A Thulium laser at 30W and a 400 micron fiber placed through a robot arm to excise and achieve hemostasis during resection of renal masses. The masses were localized intraoperatively with a 10mm laparo...

متن کامل

Single instrument for hemostatic control in laparoscopic partial nephrectomy in a porcine model without renal vascular clamping.

PURPOSE To test the viability of a new device to obtain hemostasis during laparoscopic partial nephrectomy (LPN) without vascular clamping. MATERIALS AND METHODS We performed a comparative experimental study between a new radiofrequency (RF)-assisted device consisting of a handheld instrument that simultaneously conducts coagulation and cutting tasks without hilar clamping vs a standard techn...

متن کامل

Retrograde renal cooling to minimize ischemia.

OBJECTIVE During partial nephrectomy, renal hypothermia has been shown to decrease ischemia induced renal damage which occurs from renal hilar clamping. In this study we investigate the infusion rate required to safely cool the entire renal unit in a porcine model using retrograde irrigation of iced saline via dual-lumen ureteral catheter. MATERIALS AND METHODS Renal cortical, renal medullary...

متن کامل

Zero ischemia laparoscopic partial thulium laser nephrectomy.

BACKGROUND AND PURPOSE Laser technology presents a promising alternative to achieve tumor excision and renal hemostasis with or without hilar occlusion, yet its use in partial nephrectomy has not been significantly evaluated. We prospectively evaluated the thulium:yttrium-aluminum-garnet laser in laparoscopic partial nephrectomy (LPN) in our institution over a 1-year period. PATIENTS AND METH...

متن کامل

Robotic Partial Nephrectomy Using Robotic Bulldog Clamps

BACKGROUND AND OBJECTIVES The need for a skilled assistant to perform hilar clamping during robotic partial nephrectomy is a potential limitation of the technique. We describe our experience using robotic bulldog clamps applied by the console surgeon for hilar clamping. METHODS A total of 60 consecutive patients underwent robotic partial nephrectomy, 30 using laparoscopic bulldog clamps appli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endourology

دوره 21 9  شماره 

صفحات  -