Rigidity of unilateral external fixators--a biomechanical study.
نویسندگان
چکیده
INTRODUCTION External fixation is the primary choice of temporary fracture stabilisation for specific polytrauma patients. Adequate initial fracture healing requires sufficient stability at the fracture site. The purpose of this study was to compare the rigidity of the Dynafix DFS(®) Standard Fixator (4 joints) with the Orthofix ProCallus Fixator(®) (2 joints), which differ in possibilities for adapting the configuration for clinical needs. MATERIALS AND METHODS Both devices were tested 10 times in a standardised model. In steps of 10N, loading was increased to a maximum of 160N in parallel, transversal and axial direction (distraction and compression). Translation resultant and rotation resultant were calculated. RESULTS With a force of 100N in parallel direction the mean translation resultant (Tr(mean)) of the Dynafix DFS(®) Standard Fixator (6.65±1.43mm) was significantly higher than the ProCallus Fixator(®) (3.29±0.83mm, p<0.001; Student's t-test). With a maximum load of 60N in transverse direction the Tr(mean) of the Dynafix DFS(®) Standard Fixator was significantly lower (8.14±1.20mm versus 9.83±0.63mm, p<0.005). Translation was significantly higher with the Dynafix DFS(®) Standard Fixator, for both distraction (2.13±0.32mm versus 1.69±0.44mm, p<0.05) and compression (1.55±1.08mm versus 0.15±0.33mm, p<0.005). The mean rotation resultant (Rr(mean)) at 160N distraction was lower for the Dynafix DFS(®) Standard Fixator (0.70±0.17° versus 0.97±0.21°, p<0.005). CONCLUSIONS Both fixators were most sensitive to transverse forces. The Dynafix DFS(®) Standard Fixator was less rigid with parallel and axial forces, whereas transverse forces and rotation at distraction forces favoured the Dynafix DFS(®) Standard Fixator. Repeated heavy loading did not influence the rigidity of both devices.
منابع مشابه
A biomechanical analysis of the Ilizarov external fixator.
Five configurations of the Ilizarov fixator were analyzed in vitro. The overall stiffness, shear stiffness, and axial motion of the fracture site were determined. The data were compared with the results of eight conventional one-half frame fixators previously tested in the same manner. The Ilizarov fixator allowed significantly more axial motion at the fracture site during axial compression tha...
متن کاملA more patient-friendly use of circular fixators in deformity correction
Purpose The evaluation of a construction that allows the exchange of circular and unilateral external fixators on the same fixation pins to the bone in outpatient circumstances during bone lengthening and alignment procedures. Methods Nine children were treated with this concept. After bone lengthening and alignment, the circular fixators were exchanged for unilateral fixators in the outpatient...
متن کاملA Biomechanical Comparison between Taylor’s Spatial Frame and Ilizarov External Fixator
ABSTRACT Taylor's spatial frame (TSF) and Ilizarov external fixators (IEF) are two circular external fixator commonly used to address complex deformity and fractures. There is currently no data available comparing the biomechanical properties of these two external fixators. This study looks into the mechanical characteristics of each system. TSF rings with 6 oblique struts, 4 tube connectors, 4...
متن کاملResults of application of external fixation with different types of fixators.
INTRODUCTION Extra-focal or external fixation is the method of fracture fixation through the healthy part of the bone using pins or wires. OBJECTIVE The aim was to determine which external splints (Ortofix, Mitković, Charnley and Ilizarov) had the best biomechanical properties in primary stabilization of spiral, transverse and commutative bone fractures. METHODS To determine the investigati...
متن کاملComparison of four reconstructive methods for diaphyseal defects of the humerus after tumor resection.
The objective of the current study was to compare quantitative data on the biomechanical analysis of different techniques for fixation of intercalary bone defects of the humerus, by means of consistently applied methodology on composite models. A total of 25 humeral specimens of composite models were used. An intercalary defect was created and reconstructed using plates, intramedullary nails, e...