Accuracy of pharmacokinetic models for predicting plasma fentanyl concentrations in lean and obese surgical patients: derivation of dosing weight ("pharmacokinetic mass").

نویسندگان

  • Kinichi Shibutani
  • Mario A Inchiosa
  • Keisuke Sawada
  • Mosses Bairamian
چکیده

BACKGROUND The currently available pharmacokinetic models for fentanyl were derived from normal weight patients and were not scaled to body weight. Their application to obese patients may cause overprediction of the plasma concentration of fentanyl. This study examined the influence of body weight on the predictive accuracy of two models (Anesthesiology 1990; 73:1091-102 and J Pharmacol Exp Ther 1987; 240:159-66). Further, we attempted to derive suggested dosing mass weights for fentanyl that improved predicted accuracy. METHOD Seventy patients undergoing major elective surgery with total body weight (TBW) <85 kg and body mass index <30 (Group L) and 39 patients with TBW >/=85 kg and body mass index >30 (Group O) were studied. In Group L and Group O, the mean TBW was 69 kg, and 125 kg, respectively and the mean body mass index in Group L and Group O was 24 and 44, respectively. Fentanyl infusion was used during surgery and postoperatively for analgesia. Plasma fentanyl concentrations were measured and predicted concentrations were obtained by computer simulation; 465 pairs of measured and predicted values were obtained. RESULTS The influence of TBW on the performance errors of the original two models was examined with nonlinear regression analysis. Shafer error versus TBW showed a highly significant negative relationship (R squared = 0.689, P < 0.001); i.e., the Shafer model systematically overestimated fentanyl concentration as weight increased. The Scott and Stanski model showed greater variation (R squared = 0.303). We used the exponential equation for Shafer performance error versus TBW to derive suggested dosing weights ("pharmacokinetic mass") for obese patients. The pharmacokinetic mass versus TBW curve was essentially linear below 100 kg (with slope of 0.65) and approached a plateau above 140 kg. For patients weighing 140 to 200 kg, dosing weights of 100-108 kg are projected. Total body clearance (ml/min) showed a strong linear correlation with pharmacokinetic mass (r = 0.793; P < 0.001), whereas the relationship with TBW was nonlinear. CONCLUSION Actual body weight overestimates fentanyl dose requirements in obese patients. Dosing weight (pharmacokinetic mass) derived from the nonlinear relationship between prediction error and TBW proved to have a linear relationship with clearance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pharmacokinetic mass of fentanyl for postoperative analgesia in lean and obese patients.

BACKGROUND We previously proposed dosing weights for fentanyl, termed 'pharmacokinetic mass', that span the total body weight (TBW) range from 40 to 210 kg. In this study, we examined the relationships among fentanyl doses needed to achieve postoperative analgesia, corresponding plasma fentanyl concentrations, and pharmacokinetic mass in lean and obese patients undergoing abdominal surgery. M...

متن کامل

Pharmacokinetic Studies on Oximes in Organophosphate Poisoning: A Mini Review

Organophosphate (OP) poisoning is one of the most common causes of poisoning in developing countries especially in Southeastern Asia. Poisoning with phosphorus-containing organic chemicals or OP compounds can be managed with antidotes like oximes which are potential reactivators of acetylcholinesterase (AChE). The efficacy of oxime therapy in OP poisoned patients mainly depends upon various fac...

متن کامل

Dosing Ethambutol in Obese Patients

Deshpande et al. conclude that ethambutol (EMB) doses of 50 mg/kg of body weight twice a week would be the optimal clinical dose for the treatment of Mycobacterium avium (2). This was based on pharmacokinetic-pharmacodynamic studies using a hollow-fiber system model of intracellular M. avium, mimicking ethambutol human-like pharmacokinetics. This adds important information on the relationship b...

متن کامل

Dosing Ethambutol in Obese Patients

Deshpande et al. conclude that ethambutol (EMB) doses of 50 mg/kg of body weight twice a week would be the optimal clinical dose for the treatment of Mycobacterium avium (2). This was based on pharmacokinetic-pharmacodynamic studies using a hollow-fiber system model of intracellular M. avium, mimicking ethambutol human-like pharmacokinetics. This adds important information on the relationship b...

متن کامل

A universal formula based on cystatin C to perform individual dosing of carboplatin in normal weight, underweight, and obese patients.

2527 Background: It has recently been shown that it is possible to improve the prediction of carboplatin clearance by adding plasma cystatin C level (cysC), an endogenous marker of glomerular filtration rate, to the other patient characteristics routinely used for carboplatin individual dosing, namely serum creatinine (Scr), body weight (BW), age, and sex. This multi-center pharmacokinetic stud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 101 3  شماره 

صفحات  -

تاریخ انتشار 2004