Multielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation for Paroxysmal Atrial Fibrillation: A Multinational Multicenter Randomized Clinical Trial.
نویسندگان
چکیده
BACKGROUND Single-shot ablation techniques may facilitate safe and simple pulmonary vein isolation to treat paroxysmal atrial fibrillation. Multielectrode pulmonary vein isolation versus single tip wide area catheter ablation-paroxysmal atrial fibrillation is the first multinational, multicenter, prospective, noninferiority randomized clinical trial comparing multielectrode-phased radiofrequency ablation (MEA) to standard focal irrigated radiofrequency ablation (STA) using 3-dimensional navigation. METHODS AND RESULTS Patients with paroxysmal atrial fibrillation were randomized to MEA (61 patients) or STA (59 patients). Preprocedure transesophageal echocardiogram and computed tomography/magnetic resonance imaging (also 6-month postprocedure) were performed. Mean age was 57 years, 25% female sex, BMI was 28, CHA2DS2-VASc score was 0 to 1 in 82%, 8% had previous right atrial ablation, whereas all had at least 1 antiarrhythmic drug failure. The MEA group had significantly shorter mean procedure time (96±36 versus 166±46 minutes, P<0.001) and fluoroscopy time (23±9 versus 27±9 minutes, P=0.023). The total radiofrequency energy duration was 22±8 minutes for MEA versus 36±13 minutes for STA (P<0.001) with confirmed pulmonary vein isolation in all patients. Hospital admission was 1 day in both groups, without major adverse events either during the procedure or during 30-day follow-up. Two patients in the STA group had 1 PV with asymptomatic narrowing >50%. Freedom of atrial fibrillation for MEA and STA was 86.4% and 89.7% at 6 months, dropping to 76.3% and 81.0% at 12 months. CONCLUSIONS In this multicenter, randomized clinical trial, MEA and STA had similar rates of single-procedure acute pulmonary vein isolation without serious adverse events in the first 30 days. MEA had slightly lower long-term arrhythmia freedom, but showed marked and significantly shorter procedure, fluoroscopy, and radiofrequency energy times. CLINICAL TRIAL REGISTRATION URL: www.clinicaltrials.gov; Unique identifier: NCT01696136.
منابع مشابه
Multielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation for Paroxysmal Atrial Fibrillation
Catheter ablation (CA) is an accepted treatment option for symptomatic atrial fibrillation (AF). Historically, CA has been performed with a point-by-point technique, using standard focal radiofrequency catheters and 3-dimensional (3D) navigation systems, with a procedural end point of electric pulmonary vein isolation (PVI). However, this CA approach requires advanced training and operator skil...
متن کاملMultielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation-Paroxysmal Atrial Fibrillation: Is There Any Mystery in Pulmonary Vein Isolation?
In the past decade, catheter ablation of atrial fibrillation (AF) has evolved as one of the most frequently performed procedures in tertiary arrhythmia centers worldwide. With the observation of the actively firing trigger originating from within the pulmonary veins (PVs), ablation strategies have focused at least in paroxysmal AF patients on complete isolation of the PVs. Several different abl...
متن کاملMultielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation-Paroxysmal Atrial Fibrillation
In the past decade, catheter ablation of atrial fibrillation (AF) has evolved as one of the most frequently performed procedures in tertiary arrhythmia centers worldwide. With the observation of the actively firing trigger originating from within the pulmonary veins (PVs), ablation strategies have focused at least in paroxysmal AF patients on complete isolation of the PVs. Several different abl...
متن کاملA Randomized Comparison of Circular versus Single Point-By-Point Pulmonary Vein Isolation
Introduction: Point-by-point standard ablation using single-tip (conventional) catheter is the main current technique for pulmonary vein isolation (PVI) but it can be challenging. A circular, multielectrode, mapping and ablation catheter (nMARQ) may provide faster PVI. Methods: We designed a randomized comparison between circular versus conventional PVI with the primary end point of reconnectio...
متن کاملPoint-by-Point Radiofrequency Ablation Versus the Cryoballoon or a Novel Combined Approach: A Randomized Trial Comparing 3 Methods of Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation (The Cryo Versus RF Trial).
INTRODUCTION Catheter ablation of paroxysmal AF using the Cryoballoon (CRYO) has yielded similar success rates to conventional wide encirclement using radiofrequency catheter ablation (RFCA), but randomized data are lacking. Pilot data suggested a high success rate with a combined approach (COMBINED) using wide encirclement with RFCA followed by 2 CRYO applications to each vein. We compared the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 9 4 شماره
صفحات -
تاریخ انتشار 2016