Cortical blood flow: thermal diffusion vs isotope clearance.

نویسندگان

  • L P Carter
  • R Erspamer
  • W J Bro
چکیده

A thermal diffusion flow probe incorporating a Peltier stack has been found to give a quantitative dynamic assessment of cortical blood flow in both the laboratory and clinical settings. Further calibration characteristics of the probe were evaluated by correlation with the fast component of Xe133 clearance in cats. The correlation has some linear characteristics but is better defined by the equation: CBFp = phi(1/delta V - 1/delta Vo) Where CBFp is flow in ml/100 g/min, delta V is the voltage difference of the thermocouples, and delta Vo is the voltage difference of the thermocouples with no flow, which was 342.8 +/- 12.9 microv. Phi describes the characteristics of the probe and was determined to be 52,431.2 +/- 4796.3. The average deviation of the calculated curve from the experimental data points was +/- 6.3. The calculated phi differed markedly from the mean when Xe133 fast component flows were less than 35 ml/100 g/min. This is evidence that CBF as measured by Xe133 clearance analyzed by the bicompartmental technique loses accuracy at lower flows. The thermal diffusion flow probe is a good device for evaluation of flow in acute ischemia models since it can delineate abrupt flow variations. Theoretically the flow probe can accurately measure flow at ischemic levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S1010-7940(02)00039-8

Objectives: There has been no method which can measure regional myocardial blood flow in real-time and continuously. The purpose of this study was to validate myocardial blood flow measurement using a thermal diffusion method. For this purpose, myocardial blood flow measurement was performed using the thermal diffusion method and the electrolytic hydrogen clearance method. Methods: Seven pigs w...

متن کامل

Comparison of local cerebral blood flow determined by thermal and hydrogen clearance.

Local cerebral blood flow (1CBF) was measured simultaneously in ten cats with (1) a large surface thermal diffusion probe resting on the cortex and (2) hydrogen clearance curves from implanted electrodes surrounding the thermal probe. A close correlation was found between 1CBF values obtained by the two methods. Since hydrogen clearance is accepted as quantitative, the data suggest that the the...

متن کامل

Cortical blood flow in controlled hypotension as measured by thermal diffusion.

A thermal diffusion flow probe which gave a continuous, dynamic, quantitative record of cortical blood flow (CBF) was used to assess CBF in experimental animals with controlled hypotension. Acute hypotension was produced by trimethaphan camsylate, halothane, and sodium nitroprusside. Halothane produced less reduction in CBF per drop in blood pressure than the other two agents.

متن کامل

Photoacoustic thermal diffusion flowmetry

Thermal Diffusion Flowmetry (TDF) (also called Heat Clearance Method or Thermal Clearance Method) is a longstanding technique for measuring blood flow or blood perfusion in living tissues. Typically, temperature transients and/or gradients are induced in a volume of interest and the temporal and/or spatial temperature variations which follow are measured and used for calculation of the flow. In...

متن کامل

Gradients in the regional rates of myocardial rubidium-86 clearance in tranquilized dogs.

In order to determine what gradients in local rates of myocardial blood flow are present in the resting hemodynamic state, the regional rates of myocardial clearance of Rb were measured in dogs tranquilized with chlorpromazine. The clearance rate in the left ventricle corresponded to an average coronary flow of 11.7 ml/g per 10 min. Estimated right ventricular flow was 7.1 ml/g per 10 min and l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 12 4  شماره 

صفحات  -

تاریخ انتشار 1981