Experimental consideration of capillary chromatography based on tube radial distribution of ternary mixture carrier solvents under laminar flow conditions.

نویسندگان

  • Naoya Jinno
  • Masahiko Hashimoto
  • Kazuhiko Tsukagoshi
چکیده

A capillary chromatography system has been developed based on the tube radial distribution of the carrier solvents using an open capillary tube and a water-acetonitrile-ethyl acetate mixture carrier solution. This tube radial distribution chromatography (TRDC) system works under laminar flow conditions. In this study, a phase diagram for the ternary mixture carrier solvents of water, acetonitrile, and ethyl acetate was constructed. The phase diagram that included a boundary curve between homogeneous and heterogeneous solutions was considered together with the component ratios of the solvents in the homogeneous carrier solutions required for the TRDC system. It was found that the TRDC system performed well with homogeneous solutions having component ratios of the solvents that were positioned near the homogeneous-heterogeneous solution boundary of the phase diagram. For preparing the carrier solutions of water-hydrophilic/hydrophobic organic solvents for the TRDC system, we used for the first time methanol, ethanol, 1,4-dioxane, and 1-propanol, instead of acetonitrile (hydrophilic organic solvent), as well as chloroform and 1-butanol, instead of ethyl acetate (hydrophobic organic solvent). The homogeneous ternary mixture carrier solutions were prepared near the homogeneous-heterogeneous solution boundary. Analyte mixtures of 2,6-naphthalenedisulfonic acid and 1-naphthol were separated with the TRDC system using these homogeneous ternary mixture carrier solutions. The pressure change in the capillary tube under laminar flow conditions might alter the carrier solution from homogeneous in the batch vessel to heterogeneous, thus affecting the tube radial distribution of the solvents in the capillary tube.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluidic Behavior of Polymer Compounds in an Open-Tubular Capillary with Ternary Mixed Carrier Solvents under Laminar Flow Conditions

An open-tubular capillary chromatography is developed based on tube radial distribution of the ternary mixed carrier solvents of water-hydrophilic/hydrophobic organic under laminar flow conditions. This is called “tube radial distribution chromatography” (TRDC). Fluidic behavior of the polymer compounds, FluoSpheres (1.0 m diameter), was examined by the TRDC system. The ternary mixture of wate...

متن کامل

Analytical conditions and separation performance of capillary chromatography based on the tube radial distribution of aqueous-organic mixture carrier solvents under laminar-flow conditions.

We have developed a capillary chromatography system using an open capillary tube made of fused-silica, polyethylene, or poly(tetrafluoroethylene), and a water-hydrophilic-hydrophobic organic mixture carrier solution. This tube radial distribution chromatography (TRDC) system works under laminar-flow conditions. In this study, the following analytical conditions in the TRDC system using a fused-...

متن کامل

Fundamental research and application of the specific fluidic behavior of mixed solvents in a microspace.

The author herein reviews a specific microfluidic behavior exhibited by mixed-solvent solutions in a microspace, coined as the tube radial distribution phenomenon (TRDP). The specific fluidic behavior was observed in the following solution systems: ternary water-hydrophilic/hydrophobic organic solvents, water-surfactant, water-ionic liquid, and fluorous/organic solvents. When the mixed homogene...

متن کامل

Tube radial distribution phenomenon of ternary mixed solvents in a microspace under laminar flow conditions.

When ternary mixed solutions of water-hydrophilic/hydrophobic organic solvents are fed into a microspace under laminar flow conditions, the solvent molecules are radially distributed in the microspace. The specific fluidic behavior of the solvents is termed "tube radial distribution phenomenon" (TRDP). In this study, water-acetonitrile-ethyl acetate mixed solutions (3:8:4 volume ratio) containi...

متن کامل

Micro-flow separation system using an open capillary tube that works under laminar flow conditions.

A micro-flow separation system was developed using an open capillary, fused-silica or polyethylene tube, and an aqueous-organic mixture (water-acetonitrile-ethyl acetate mixture) as a carrier solution. A model analyte solution containing 2,6-naphthalenedisulfonic acid and 1-naphthol was injected into the capillary tube by a gravity method. The analyte solution was subsequently delivered through...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2011