Multiple mechanical valve replacement surgery comparison of St. Jude Medical and CarboMedics prostheses.
نویسندگان
چکیده
OBJECTIVE The experience with the St. Jude Medical (SJM) and CarboMedics (CM) bileaflet mechanical prostheses was evaluated to determine thromboembolic and hemorrhagic complications and predictive risk factors. METHODS From 1989 to 1994, a total of 246 patients had multiple valve replacement (SJM, 140; CM, 106); concomitant procedures 20.3% (50) [coronary artery bypass 10.6% (26)] and 53.7% (132) previous cardiac surgery, primarily valve replacement procedures. The pre-operative variables [coronary artery disease, previous cardiovascular surgery, concomitant procedures, valve lesion (except mitral stenosis), status, atrial fibrillation, and NYHA III/IV] did not distinguish the prosthesis-type (pNS). RESULTS The prosthesis-type and the pre-operative variables, including atrial fibrillation, were not predictive of overall thromboembolism (TE). The linearized rate of total TE events for overall multiple replacements (MR) was 5.4%/patient-year (minor, 2.52; major 2.85); the total TE for CM and SJM was 5.4%/patient-year, respectively. The < or = 30 day major TE crude rate was 0.82%, while the > 30 day major event rate was 2.7%/patient-year. Of the total (major and minor) TE events 100% (3) of < or = 30 days and 72% (29), > 30 days had an INR < 2.5 at or immediately prior to the event. The thrombosis rate (included in total TE events) was 0.67%/patient-year (4 events, 100% INR < 2.5). Of the various TE event categories the prosthesis-types (CM and SJM) were not differentiated (pNS). The freedom, at 5 years, from major/fatal TE, thrombosis and hemorrhage from anticoagulation was 89.3 +/- 3.8% for CM and 87.9 +/- 3.7% for SJM and, 91.3 +/- 3.5% and 89.3 +/- 3.7%, respectively, (pNS) exclusive of early events. CONCLUSIONS The performance of the CarboMedics and St. Jude Medical prostheses in multiple valve replacement surgery in this non-randomized prospective study revealed no significant differences in performance with regard to thromboembolic and hemorrhagic complications.
منابع مشابه
Leaflet arrest in St Jude Medical and CarboMedics valves: an experimental study.
OBJECTIVE Two patients who suffered acute failure of their St Jude Medical Masters aortic valve prostheses due to leaflet arrest that were unrelated to suture material are presented. It was hypothesized that the valves failed because force applied to bear upon the valve annulus caused the hinge mechanism to become restricted or to arrest. METHODS A study was designed to measure the force that...
متن کاملClosing sounds and related complaints after heart valve replacement with St Jude Medical, Duromedics Edwards, Björk-Shiley Monostrut, and Carbomedics prostheses.
OBJECTIVE To measure the noise produced and related subjective complaints after implantation of four different mechanical heart valve prostheses and to identify further factors related to the patient and prosthesis that influence noise generation and complaints. DESIGN Sound pressure was measured 5 and 10 cm and 1 m from the point of maximal impulse on the body surface by a calibrated meter i...
متن کاملPii: S1010-7940(99)00087-1
Objective: The experience with the Carbomedics (CM) and the St. Jude Medical (SJM) bilea ̄et mechanical prostheses was evaluated to determine thromboembolic and hemorrhagic complications and predictive risk factors. Methods: From 1989 to 1994, a total of 625 patients had mitral valve replacement (CM, 240; SJM, 385); 32.5% (203), concomitant procedures and 32.8% (205), previous cardiac surgery, p...
متن کاملClinical performance of biological and mechanical prostheses.
Prosthetic valve replacement remains the most viable alternative for the treatment of severely diseased heart valves. The cumulative experience of mechanical protheses and bioprostheses was evaluated for a 10-year performance comparison: Carpentier-Edwards standard porcine bioprosthesis (CE-S), 1,214 operations; Carpentier-Edwards supraannular porcine bioprosthesis (CE-SAV), 2,489; and mechanic...
متن کاملFive-year follow-up after heart valve replacement with the CarboMedics bileaflet prosthesis.
BACKGROUND The CarboMedics valve is a relatively new, low-profile, bileaflet, mechanical prosthesis. The results of a prospective follow-up study after valve replacement with this prosthesis in a university hospital are presented. METHODS We implanted 640 CarboMedics prostheses in 583 patients in the aortic (n = 359), mitral (n = 167), or aortic and mitral positions (double valve replacement;...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 13 2 شماره
صفحات -
تاریخ انتشار 1998