Widespread dissemination of metal debris from implants.

نویسندگان

  • C P Case
  • V G Langkamer
  • C James
  • M R Palmer
  • A J Kemp
  • P F Heap
  • L Solomon
چکیده

In a post-mortem study, we compared subjects with metal implants with and without visible wear with an age-matched control group to determine the extent and effects of dissemination of wear debris. In subjects with stainless-steel and cobalt-chrome prostheses metal was found in local and distant lymph nodes, bone marrow, liver and spleen. The levels were highest in subjects with loose, worn joint prostheses and the main source of the debris was the matt coating. Metal levels were also raised in subjects with implants without visible wear and, to a less extent, in those with dynamic hip screws. Necrosis of lymph nodes was seen in those cases with the most wear, and potential damage to more distant organs such as the bone marrow, liver and spleen in the long term cannot be discounted. The consequences for the immune system and the role of metal dissemination in the possible induction of neoplasia are discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is wear debris responsible for failure in alumina-on-alumina implants?

BACKGROUND AND PURPOSE Ceramic-on-ceramic articulation is an attractive alternative to metal-on-polyethylene (PE) bearings, but little is known about the in vivo effects induced by dissemination of alumina wear debris in the periprosthetic tissues. We hypothesized that wear debris is not the main factor responsible for loosening and failure of the implant but that mechanical problems caused by ...

متن کامل

A review of the biologic effects of spine implant debris: Fact from fiction

BACKGROUND Biologic-reactivity to implant-debris is the primary determinant of long-term clinical performance. The following reviews: 1) the physical aspects of spinal-implant debris and 2) the local and systemic biologic responses to implant debris. METHODS Methods included are: 1) gravimetric wear analysis; 2) SEM and LALLS; 3) metal-ion analysis; 4) ELISA, toxicity testing, patch testing; ...

متن کامل

Surface Characterization of Retrieved Metal-on-Metal Total Hip Implants from Patients with Adverse Reaction to Metal Debris

The use of metal-on-metal (MoM) total hip implants has decreased recently due to reports of high failure rates and adverse local tissue reaction (ALTR). It has been hypothesized that wear metal debris released from CoCr bearing surfaces may provoke delayed hypersensitivity reactions. The goal of this study is to evaluate the microscopic bearing surface characteristics of implants revised due to...

متن کامل

Effects of CoCr metal wear debris generated from metal-on-metal hip implants and Co ions on human monocyte-like U937 cells.

Hip resurfacing with cobalt-chromium (CoCr) alloy was developed as a surgical alternative to total hip replacement. However, the biological effects of nanoparticles generated by wear at the metal-on-metal articulating surfaces has limited the success of such implants. The aim of this study was to investigate the effects of the combined exposure to CoCr nanoparticles and cobalt ions released fro...

متن کامل

In Vitro Assessment of Serum-Saline Ratios for Fluid Simulator Testing of Highly Modular Spinal Implants With Articulating Surfaces

BACKGROUND The increasing complexity of articulating spinal implants prohibits the use of serum-supplemented simulator fluid testing because multicomponent interfaces retain residual protein and preclude gravimetric measurement. Our original hypothesis was that simulator testing of a posterior dynamic stabilization implant that has metal-on-metal articulating bearings will not produce dramatica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 76 5  شماره 

صفحات  -

تاریخ انتشار 1994