Surgical Management of Recurrent Tracheocarotid Fistula following Endovascular Stent Placement.
نویسندگان
چکیده
We report the case of a 25-year-old woman who developed a tracheocarotid fistula secondary to an infected endovascular stent placed in the right carotid artery after the patient experienced hemorrhage on her first tracheostomy change. The patient originally had the tracheostomy placed at an outside hospital in September 2014, due to prolonged intubation after a motor vehicle accident. The patient presented to the otolaryngology service with an acute tracheal hemorrhage. This necessitated a neck exploration, median sternotomy, right carotid stent removal with subclavian to carotid bypass, and sternocleidomastoid flap reconstruction. This paper addresses the epidemiology and anatomy of a tracheocarotid fistula and discusses methods to treat such a complication.
منابع مشابه
Subclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis
Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...
متن کاملRecurrent Carotid Cavernous Fistula Originating from a Giant Cerebral Aneurysm after Placement of a Covered Stent
We report the case of a recurrent carotid cavernous fistula (CCF) originating from a giant cerebral aneurysm (GCA) after placement of a covered stent. A 47-year-old woman presented with sudden onset of severe headache, and left-sided exophthalmos and ptosis. Cerebral angiography revealed a CCF caused by rupture of a GCA in the cavernous segment of the left internal carotid artery. Two covered s...
متن کاملSuccessful management of an aorto-gastric fistula occurring 15 years after oesophagectomy with covered aortic stent graft placement followed by open surgery
Aorto-gastric fistula (AGF) is an uncommon and life threatening complication of oesophagectomy. Usually occurring in the immediate weeks following the procedure at anastomosis lines, this case describes a rare development of an AGF 15 years after an oesophagectomy due to the presence of a benign ulcer. Initially successful endovascular stenting of the thoracic aorta was followed by re-bleed, fu...
متن کاملAn Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess
Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...
متن کاملRecurrent Tracheoinnominate Artery Fistula due to Stent Graft Fracture
Tracheoinnominate artery fistula (TIF) is one of the most dangerous complications after tracheostomy, and fetal even after surgical repair. Recently, endovascular stent has been introduced as an option for the treatment of TIF. Unfortunately, endovascular stent repair could not replace the surgery due to rare clinical reports about the long-term follow-up and complications of stent graft. More ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Case reports in otolaryngology
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015