Performance evaluation of the PC-2048: a new 15-slice encoded-crystal PET scanner for neurological studies.
نویسندگان
چکیده
Initial experience is reported with the Scanditronix PC 2048-15B, a 15-slice positron emission tomography (PET) system using multicrystal/multiphoto-multiplier modules to obtain high spatial resolution. Random and scattered events are reduced using an orbiting (68)Ge rod source for transmission scans by only accepting coincidence lines which intersect the instantaneous position of the source. Scatter correction of the emission data is removed with a deconvolution kernel, random and dead-time correction by the use of observed singles rates. The peak count rates are 11.7/20.0 Kcps for the direct cross slices at concentrations of 4.5/5.1 muCi/cc. respectively. Over the radial range 0-9 cm from the ring center, radial transverse resolution is 4.6-6.4 mm, aid tangential transverse resolution is 4.6-5.1 mm using a Hanning filter. Over the same range, axial resolution varies from 6.1-6.2 mm in direct slices and from 5.4-7.1 mm in cross slices. This near-isotropic resolution allows collection of image volume data with no preferred direction for signal averaging errors.
منابع مشابه
Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE
Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...
متن کاملValidation and evaluation of a GATE model for MAMMI PET scanner
Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard. Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...
متن کاملDesign and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling
Introduction: There has been a curiosity about the spheroid geometry for PET scanners developments since several years ago, therefore in this study, we are aiming to evaluate the performance of this geometry and compare its performance with cylindrical geometry using Monte Carlo simulation. Methods: We simulated a spheroid geometry with a radius of 199 mm...
متن کاملEvaluation of a Neck-Shield for Use During Neurological Studies with a Whole-Body PET Scanner
It is well known that the shielding against out-of-field scattered radiation is not very effective on whole body PET scanners operated with their slice-defining septa retracted. Additional shielding can be employed during neurological studies since the diameter of the head is much less than the field of view required for imaging the human torso. We have designed, built and tested (on the CTI HR...
متن کاملComparison of 6 PET scanners, a simulation study [Persian]
Introduction: Due to the large number of PET systems available in the market, it is not very easy to decide about the scanner of choice. Conducting a research in order to compare all different PET scanners is very time consuming and expensive and practically impossible. However, such comparison may be conducted using PET simulators. In this study, the performance of 6 different PET scanne...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE transactions on medical imaging
دوره 10 1 شماره
صفحات -
تاریخ انتشار 1991