Doppler evaluation of blood flow in fetal inferior vena cava during 48-hours Atosiban administration in spontaneous preterm labor.

نویسندگان

  • Mariusz Grzesiak
  • Rehana B Ahmed
  • Jan Wilczynski
چکیده

OBJECTIVES The aims were to evaluate whether any changes in blood flow in fetal inferior vena cava (IVC) are observed during Atosiban tocolysis within the first 48 hours of therapy. METHODS Detailed Doppler evaluation of blood flow in fetal IVC was performed prior to Atosiban administration and after 24 and 48 hours respectively. Maternal and fetal heart rate was assessed. IVC Doppler indices, such as, S/D (systole/diastole), PVIV (peak velocity index for the vein) and PLI (preload index) were calculated. To determine changes over time in all study variables, analysis of variance (ANOVA) for repeated measurements was used and followed by Tukey-Kramer's post hoc test. The effects of additional clinical covariates were checked. RESULTS Maternal heart rate was not altered significantly during Atosiban administration. No significant changes in FHR (fetal heart rate) as well as following IVC Doppler parameters (S/D, PVIV) were recorded after 24/48 hours of tocolytic treatment. The fetal IVC PLI values were significantly reduced after 24 hours and 48 hours of treatment. The changes in PLI values when comparing 24 and 48 hours results were not statistically significant. CONCLUSIONS As the questions about drug safety appeared after the animal study had been published about possible myocyte injury, detailed Doppler evaluation of IVC blood flow was performed. It revealed the changes in preload conditions which could be a reflection of successful Atosiban tocolytic treatment. No hemodynamic changes in IVC were noted, suggesting the presence of fetal acidemia due to possible heart damage was observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

48-hours administration of fenoterol in spontaneous preterm labor - does it affect fetal preload?

OBJECTIVE to investigate whether any changes in the preload index (PLI) occur within the first 48 hours of fenoterol intravenous tocolysis. MATERIAL AND METHODS Doppler evaluation of placental and fetal circulation was performed in 36 pregnant women prior to fenoterol administration and after 24/48 hours. Measurements were obtained from a longitudinal section of the inferior vena cava (IVC) a...

متن کامل

Preliminary report of 48-hours Atosiban administration in spontaneous preterm labor - Doppler blood flow assessment of placental and fetal circulation.

OBJECTIVES The aims were to investigate whether there are any changes in placental and fetal circulation during Atosiban tocolysis within the first 48 hours of therapy. METHODS Detailed Doppler evaluation of placental and fetal circulation was performed prior to Atosiban administration and thereafter at 24 and 48 hours. Maternal heart rate and the pulsatility index (PI) in both uterine arteri...

متن کامل

I-46: Obstetrical Doppler

Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...

متن کامل

48-hours administration of nifedipine in spontaneous preterm labor - Doppler blood flow assessment of placental and fetal circulation.

OBJECTIVES The aims were to assess the placental and fetal circulation during nifedipine tocolysis within the first 48 hours of therapy. METHODS Placental and fetal circulation was assessed in Doppler ultrasound examination prior to nifedipine administration and then after 24 and 48 hours. Maternal heart rate and PI in uterine arteries were evaluated as well as FHR, RI and PI of UA and MCA. E...

متن کامل

48-hours administration of fenoterol in spontaneous preterm labor - Doppler blood flow assessment of placental and fetal circulation.

OBJECTIVES The aims were to investigate whether any changes in placental and fetal circulation were observed during fenoterol tocolysis within the first 48 hours of therapy. MATERIAL AND METHODS Doppler evaluation of placental and fetal circulation was performed prior to fenoterol administration and then after 24 and 48 hours. Maternal heart rate and pulsatility index (PI) in uterine arteries...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neuro endocrinology letters

دوره 34 8  شماره 

صفحات  -

تاریخ انتشار 2013