MR imaging with a reduced number of encoding steps

نویسندگان

  • John B. Weaver
  • Dennis M. Healy
  • Douglas W. Warner
چکیده

Several methods have been used to obtain complete MR images from a reduced set of measured encodes 1,2,3,4,5,6. All of these techniques use some sort of a priori information to complete the incomplete data set. These techniques have had varying degrees of success in a variety of applications: imaging contrast uptake, interventional procedures, spectroscopy, fMRI contrast changes, and routine scans of a given population. In this paper we make three points: First, significant effort has been made toward finding the set of phase encodes that minimizes the expected L2 norm of the encoding error. We show that in experiments many sets of phase encodes come close to attaining the Karhunen-Loéve (K-L) limit. However, second, we show that other image quality metrics result in much more pleasing images that have much better detail than images where the L2 norm is optimized. For this purpose we use best basis algorithms to find a local trigonometric and wavelet packet bases which optimizes several cost functions including the Lp norms and entropy; the L0.25 norm gave the most pleasing results. Lastly, we show that although ringing produced by undersampling can not be eliminated it can be effectively controlled when the general shape of the object is known. Ringing renders techniques like SLIM1 impractical. We are able to control ringing by fitting the reconstructed signal to a piecewise monotonic function 7. The larger peaks are kept and the fast oscillations characteristic of ringing are eliminated. The signal can be pulled out of noise or fast oscillations when the signal energy is only one quarter of the noise energy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

B1-Gradient Based MRI Using a Multi-Element Transmit System

Introduction: Spatial signal encoding in MRI is usually performed via B0-gradients. An alternative method is the use of B1-gradients (so-called RF encoding), already suggested in the early days of MR (see, e.g., [1-3]). RF encoding offers the possibility to omit all B0-gradients, which would allow for MR scanning more or less free of acoustic noise. This advantage might be counterbalanced by lo...

متن کامل

Comparison of 1-d and 2-d surface coil arrays for accelerated volume MR imaging using sensitivity encoding

The optimum phased array combined SNR (B1weighted) [5] and SENSE g-factor were computed for various coil geometries and imaging plane orientations based on simulated field maps. Magnetic fields (B1-maps) for each coil were calculated using the Biot-Savart law. The sample noise correlations between coils which are used in calculating the optimum B1-weighted combining and SENSE g-factor [1] were ...

متن کامل

Phantom based qualitative and quantitative evaluation of artifacts in MR images of metallic hip prostheses.

PURPOSE To develop methods for qualitative and quantitative evaluation of MRI artifacts near metallic prostheses, and to compare the efficiency of different artifact suppression techniques with different types of hip prostheses. METHODS Three hip prostheses of cobalt-chromium, stainless steel, and titanium were embedded in agarose gel together with a rectilinear grid. Coronal MR images of the...

متن کامل

The modeling of induced current density in eyes from static magnetic fields produce by MR scanner

Introduction: Staff and patient Movement in static magnetic field MRI scanner induces current density in the human tissues, so cause biologic effects in people. The aim of this study was the Modelling of current density induced by moving individual with different velocities in static magnetic field of magnetic resonance imaging. Materials and Methods: current ...

متن کامل

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1996