Metrological Characterization for Vital Sign Detection by a Bioradar

نویسندگان

  • Giovanni Cerasuolo
  • Orsola Petrella
  • Luigi Marciano
  • Francesco Soldovieri
  • Gianluca Gennarelli
چکیده

In space missions, during the long isolation at extreme conditions for human health, it is of paramount importance to monitor vital parameters. One such parameter is the breathing rate. Indeed, several factors can induce some breathing anomalies during the sleep, which may cause apnea episodes. In order to act timely with the right therapy, an early diagnosis is required. Conventional devices are usually uncomfortable since they require electrodes or probes in contact with the subject. An alternative way to perform this kind of measurement in a remote sensing modality is provided by a continuous wave bioradar operating in the microwave frequency band. This is an effective contactless tool for monitoring the respiratory activity through the measurement of chest deformation due to inhalation and exhalation. The radar emits a low power electromagnetic wave at a single frequency, which is reflected by the human chest. By measuring of the phase shift between the incident and reflected wave, it is possible to detect and monitor the respiratory rate. The main contribution of this work is concerned with a metrological characterization of the continuous wave bioradar; which is a topic not thoroughly assessed in the relevant literature. In particular, the bioradar measurements are also compared with data recorded by a spirometer, which is a standard medical device that measures the air volume inhaled and exhaled by the subject. The purpose of this study is the characterization of the measurement standard uncertainty to enable the assessment of the bioradar system performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wireless Bioradar Sensor Networks for Speech Detection and Communication

Wireless multimedia sensor networks (WMSN) are emerging to serve for the collection of acoustic and image information. In the WMSN, the microphone is usually employed to function as sensor nodes for the acquisition of acoustic data. However, those microphone sensors are needed to be placed close with sound source and cannot detect sound signal through certain obstacles. To overcome the shortcom...

متن کامل

Detection and Recognition of Multi-language Traffic Sign Context by Intelligent Driver Assistance Systems

Design of a new intelligent driver assistance system based on traffic sign detection with Persian context is concerned in this paper. The primary aim of this system is to increase the precision of drivers in choosing their path with regard to traffic signs. To achieve this goal, a new framework that implements fuzzy logic was used to detect traffic signs in videos captured along a highway f...

متن کامل

Design an Intelligent Driver Assistance System Based On Traffic Sign Detection with Persian Context

In recent years due to improvements of technology within automobile industry, design process of advanced driver assistance systems for collision avoidance and traffic management has been investigated in both academics and industrial levels. Detection of traffic signs is an effective method to reach the mentioned aims. In this paper a new intelligent driver assistance system based on traffic...

متن کامل

Moisture content measurements through TDR: a metrological assessment for industrial applications

In this paper a metrological assessment on the accuracy provided by a Time Domain Reflectometry (TDR)based method for the estimation of moisture content of granular materials is proposed. In particular, comparative moisture content measurements are carried out through two different TDR instruments: an inexpensive portable unit and a high-performance unit. The main goals are first to assess a ro...

متن کامل

The effect of Orientation technique on vital sign and anxiety level of patients undergoing Endoscopic Retrograde Cholangiopancreatography (ERCP)

Background: Diagnostic and therapeutic procedures such as Endoscopic Retrograde Cholangiopancreatography (ERCP) is stressful for the patient. Aim:  to determine the influence of Orientation technique on anxiety levels and pulse rate in patients before ERCP in Talaghni hospital in 2011. Method: This study was a randomized controlled clinical trial which carried out on 70 subjects with gastrointe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Remote Sensing

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017