MR Scanner Systems Should Be Adequately Characterized in Diffusion-MRI of the Breast
نویسندگان
چکیده
Breast imaging represents a relatively recent and promising field of application of quantitative diffusion-MRI techniques. In view of the importance of guaranteeing and assessing its reliability in clinical as well as research settings, the aim of this study was to specifically characterize how the main MR scanner system-related factors affect quantitative measurements in diffusion-MRI of the breast. In particular, phantom acquisitions were performed on three 1.5 T MR scanner systems by different manufacturers, all equipped with a dedicated multi-channel breast coil as well as acquisition sequences for diffusion-MRI of the breast. We assessed the accuracy, inter-scan and inter-scanner reproducibility of the mean apparent diffusion coefficient measured along the main orthogonal directions () as well as of diffusion-tensor imaging (DTI)-derived mean diffusivity (MD) measurements. Additionally, we estimated spatial non-uniformity of (NU) and MD (NUMD) maps. We showed that the signal-to-noise ratio as well as overall calibration of high strength diffusion gradients system in typical acquisition sequences for diffusion-MRI of the breast varied across MR scanner systems, introducing systematic bias in the measurements of diffusion indices. While and MD values were not appreciably different from each other, they substantially varied across MR scanner systems. The mean of the accuracies of measured and MD was in the range [-2.3%,11.9%], and the mean of the coefficients of variation for and MD measurements across MR scanner systems was 6.8%. The coefficient of variation for repeated measurements of both and MD was < 1%, while NU and NUMD values were <4%. Our results highlight that MR scanner system-related factors can substantially affect quantitative diffusion-MRI of the breast. Therefore, a specific quality control program for assessing and monitoring the performance of MR scanner systems for diffusion-MRI of the breast is highly recommended at every site, especially in multicenter and longitudinal studies.
منابع مشابه
Comparison between MRS and DWI in MRI of breast cancer
Introduction: Breast cancer is the most common cancer in women and is the second leading cause of cancer death (after lung cancer) in people throughout the world. Today, MRI is being used because of the limitations of x-ray mammography to detect breast cancer. Non-contrast sequences were associated to CE sequences in a breast MRI protocol for the sake of appraising morphologic ...
متن کاملClinical Multiparametric MR Imaging of Breast Tumors at 7 Tesla
Magnetic Resonance Imaging (MRI) of the breast is a powerful imaging tool for the characterization, diagnosis, staging, and treatment monitoring of breast cancer. Applications at clinical magnetic field strengths (≤ 3T) have been extensively described. At 7T*, substantial improvements in image quality could be provided, if technical challenges can be overcome. In this article, the authors discu...
متن کاملDynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors
Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...
متن کاملComparison of apparent diffusion coefficient values among different MRI platforms: a multicenter phantom study.
PURPOSE We aimed to compare apparent diffusion coefficient (ADC) values among magnetic resonance imaging (MRI) scanners from different vendors. MATERIALS AND METHODS We used a custom-made phantom solution consisting of distilled water, 0.9% NaCl, 25% NaCl, and shampoo for diffusion-weighted MRI (DW-MRI) examinations. DW-MRI was performed with similar sequence parameters using six different 1....
متن کاملTreatment Response Evaluation of Breast Cancer after Neoadjuvant Chemotherapy and Usefulness of the Imaging Parameters of MRI and PET/CT
This study was aimed to evaluate the ability of imaging parameters measured on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), diffusion-weighted MRI (DWI) and positron emission tomography/computed tomography (PET/CT) to serve as response markers in breast cancer after neoadjuvant chemotherapy (NAC). In 20 patients with breast cancer, DCE-MRI and DWI using a 3 T scanner and PET/...
متن کامل