Early experiences of planning stereotactic radiosurgery using 3D printed models of eyes with uveal melanomas
نویسندگان
چکیده
OBJECTIVE The objective of this study was to determine the use of 3D printed model of an eye with intraocular tumor for linear accelerator-based stereotactic radiosurgery. METHODS The software for segmentation (3D Slicer) created virtual 3D model of eye globe with tumorous mass based on tissue density from computed tomography and magnetic resonance imaging data. A virtual model was then processed in the slicing software (Simplify3D®) and printed on 3D printer using fused deposition modeling technology. The material that was used for printing was polylactic acid. RESULTS In 2015, stereotactic planning scheme was optimized with the help of 3D printed model of the patient's eye with intraocular tumor. In the period 2001-2015, a group of 150 patients with uveal melanoma (139 choroidal melanoma and 11 ciliary body melanoma) were treated. The median tumor volume was 0.5 cm3 (0.2-1.6 cm3). The radiation dose was 35.0 Gy by 99% of dose volume histogram. CONCLUSION The 3D printed model of eye with tumor was helpful in planning the process to achieve the optimal scheme for irradiation which requires high accuracy of defining the targeted tumor mass and critical structures.
منابع مشابه
Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...
متن کاملLocal tumor control and morbidity after one to three fractions of stereotactic external beam irradiation for uveal melanoma.
BACKGROUND AND PURPOSE To evaluate prospectively local tumor control and morbidity after 1-3 fractions of stereotactic external beam irradiation (SEBI) in patients with uveal melanoma, unsuitable for ruthenium-106 brachytherapy or local resection. MATERIAL AND METHODS This phase I/II study includes 62 selected patients with uveal melanoma. The mean initial tumor height was 7.8+/-2.8 mm. With ...
متن کامل[Possibility of 3D Printing in Ophthalmology - First Experiences by Stereotactic Radiosurgery Planning Scheme of Intraocular Tumor].
Nowadays 3D printing allows us to create physical objects on the basis of digital data. Thanks to its rapid development the use enormously increased in medicine too. Its creations facilitate surgical planning processes, education and research in context of organ transplantation, individualization prostheses, breast forms, and others.Our article describes the wide range of applied 3D printing te...
متن کاملOcular arterial blood flow of choroidal melanoma eyes before and after stereotactic radiotherapy using Leksell gamma knife: 2 year follow up.
AIMS To evaluate the effect of high dose stereotactic radiotherapy on the ocular blood flow of patients with uveal melanoma. METHODS Colour Doppler imaging (CDI) was used to measure blood flow velocity and vascular resistance in the ophthalmic, short posterior, and central retinal arteries of nine patients suffering from uveal melanoma. The measurements were taken before, 6 months, 1 year, an...
متن کاملDevelopment of a prototype stereotactic collimation assembly for Neptun 10 PC linac
Background: A set of hardware stereotactic radiosurgery is designed and constructed. The scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 MV Neptun 10 PC linac. Materials and methods: One collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. Beam data, suc...
متن کامل