Evaluation of insert earphones for high-frequency bedside ototoxicity monitoring.

نویسندگان

  • Jane S Gordon
  • David S Phillips
  • Wendy J Helt
  • Dawn Konrad-Martin
  • Stephen A Fausti
چکیده

Ototoxic hearing loss is usually detected earliest through monitoring of the highest audible frequencies in individuals administered ototoxic medications. Conducting ototoxicity monitoring may require testing patients in the hospital room. This study evaluated the use of insert earphones for obtaining reliable threshold responses at bedside. Twenty adult subjects were tested during two different sessions in the sound booth and on the ward. Thresholds were obtained for frequencies from 5 to 16 kHz and at 2 kHz with the use of the KOSS Pro/4X Plus earphones and Etymotic ER-4B MicroPro insert earphones. Results indicate that ER-4B insert earphones are as reliable as KOSS earphones for testing on the ward for high-frequency ototoxicity monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-frequency thresholds: circumaural earphone versus insert earphone.

Benefits of high-frequency audiometry in monitoring hearing sensitivity of patients administered ototoxic medications are well established. High-frequency thresholds have been reported to be variable, due in part to small differences in the placement of the earphone diaphragm over the opening of the ear canal. Reliability may be improved by using insert earphones (ER-2) when obtaining high-freq...

متن کامل

Examination of Insert Ear Interaural Attenuation (IA)Values in Audiological Evaluations.

PURPOSE The purpose of this study was to evaluate Interaural Attenuation (IA) in frequency base in the insert earphones that are used in audiological assessments. METHODS Thirty healthy subjects between 18-65 years of age (14 female and 16 male) participated in our study. Otoscopic examination was performed on all participants. Audiological evaluations were performed using the Interacoustics ...

متن کامل

Test-retest reliability of high-frequency thresholds at bedside with sensorineural hearing-impaired listeners.

Previous investigations have established the reliability of high-frequency thresholds performed in a sound suite using headphones. In addition, test-retest reliability of high-frequency thresholds in adults with normal hearing in a hospital room versus a sound-treated booth has also been established. The current study evaluated the test-retest reliability of thresholds in the 8000- to 18000-Hz ...

متن کامل

Comparison of Etymotic insert and TDH supra-aural earphones in auditory brainstem response measurement.

There are few systematic comparisons of Etymotic ER-3A insert earphones versus supra-aural earphones in auditory brainstem response (ABR) measurement. We compared ER-3A insert earphones and two types of supra-aural earphones (TDH-39P and TDH-49P) in a group of normal hearing adults. Acoustic analyses revealed spectral and temporal differences among earphones. Behavioral and ABR thresholds to cl...

متن کامل

Insert earphones for speech recognition testing.

Performance-intensity functions for PB word lists were run on 19 normal-hearing subjects and 15 subjects with sensorineural hearing losses. Comparisons were made between standard supra-aural earphones (TDH-49P) and insert phones (ER-3A). Results showed that, at least for the higher sensation levels where word recognition tests are usually performed, the phones may be used interchangeably. Using...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 42 3  شماره 

صفحات  -

تاریخ انتشار 2005