Black intraocular lenses: near infra-red light transmission may risk treatment failure
نویسندگان
چکیده
Intractable diplopia occurs in approximately 0.8% of patients following strabis-mus surgery, with considerable detriment to visual quality of life. Long-term therapeutic occlusion is required to permit functional vision. Black intraocular lens (IOL) implantation is an effective therapeutic option associated with high rates of postoperative satisfaction. 1 Black IOL implantation entails a cost to the public sector or patient but this may be offset by long-term clinical and social benefits and fewer hospital visits. A distinction has emerged between black IOLs that transmit near-infrared (NIR) light and those producing total occlusion of all wavelengths of light (figure 1). 2 Morcher black IOLs transmit NIR light exponentially from 720 nm, with 100% transmission over 820 nm, permitting posterior segment imaging with scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT). 2 This property offers a distinct clinical advantage; SLO/OCT may detect life-threatening retinal and optic nerve diseases, such as choroidal melanoma. 2 The intended benefit of black IOL implantation is occlusion of light. Enigmatic perception of light across NIR-transmitting black IOLs has been reported widely without any consensus on the mechanism of light perception. Four hypotheses have been suggested: (1) Perception of light by long-wavelength, L-cone photoreceptors due to NIR light transmission across Morcher black IOLs 2 5 (2) Para-optical light leakage in patients with large scotopic pupil diameters, 4 (3) Light transmission across the intact sclerochoroidal tunic, 4 (4) Non-organic light perception. Retrospective examination of all black IOL case series reported in the literature (table 1) strongly supports the hypothesis Figure 1 Black IOLs in clinical use. Near-infrared (NIR)-transmitting black IOLs: (A) 85F PMMA IOL (6 mm optic, 12 mm overall), (B) 6S PMMA IOL (10 mm optic, 12 mm overall), (C) 80D PMMA IOL (6 mm optic, 13.5 mm overall). All NIR-transmitting Black Lotus 80D PMMA IOL are PostScript of NIR light perception across NIR-transmitting black IOLs as the primary mechanism underlying treatment failure—defined as troublesome persistence of light perception or diplopia despite black IOL implantation. Twenty-three patients have been reported across four case series, which document preoperative and postoperative visual acuities of patients implanted with NIR-transmitting black IOLs 1 3–5 (table 1). Twenty-one patients (91%) recorded light perception vision through the black IOL postoperatively. Two patients experienced complete occlu-sion of light after NIR-transmitting black IOL implantation 4 ; both patients had optic neuropathies documented preoperatively (compressive and demyelinating, respectively). Optic neuropathies are associated with loss of red–green chromatic discrimination …
منابع مشابه
Near-infrared transillumination photography to detect anterior uveal melanomas through black IOLs
Krohn et al describe a novel photographic technique using near-infrared (NIR) transillumination to detect peripheral anterior choroidal and ciliary body melanomas not visible on slit lamp examination. The described imaging technique uses a broad spectrum background light source to illuminate the fundus and external photography with a 720–1100 nm NIR filter to evaluate anterior uveal masses, per...
متن کاملLight transmission through intraocular lenses with or without yellow chromophore (blue light filter) and its potential influence on functional vision in everyday environmental conditions
In this research the factors used to evaluate the light transmission through two types of acrylic hydrophobic intraocular lenses, one that contained yellow chromophore that blocks blue light transmission and the other which did not contain that filter, were defined according to various light condition, e.g., daylight and at night. The potential influence of light transmission trough intraocular...
متن کاملPolychromatic Image Performance of Diffractive Bifocal Intraocular Lenses: Longitudinal Chromatic Aberration and Energy Efficiency.
PURPOSE The study evaluated-theoretically and experimentally-the longitudinal chromatic aberration (LCA) and through-focus energy efficiency (TF-EE) of diffractive-refractive bifocal intraocular lenses (2f-IOLs). METHODS Four aspheric 2f-IOLs (Tecnis +4.00 diopter [D] ZMA00, +2.75 D ZKB00, and AcrySof +4.0 D SN6AD3, +2.5 D SV25T0) of same base power 30 D, but different design, additional (add...
متن کاملAction Spectrum for Photobleaching of Human Lenses by Short Wavelength Visible Irradiation
PURPOSE Cataract is the world-leading cause of blindness. In search for a new treatment of cataract we have found that the yellow discolouration of aged human lenses can be photobleached using a non-invasive, infra-red, femtosecond laser treatment. These results were presented in an earlier PlosOne publication. The objective of the study was to characterize the single-photon photobleaching acti...
متن کاملOpaque intraocular lens implantation
Correspondence: CK Patel The Oxford Eye Hospital, West Wing, John Radcliffe Hospital, Headley Way, Headington, Oxford, OX3 9DU, United Kingdom Tel +44 18 6523 4736 Fax +44 18 6524 0097 Email [email protected] We read with great interest the recent article by Lee et al, who described their clinical experience with three patients who underwent primary implantation of Morcher (Stuttgart, Germ...
متن کامل