Precision Measurement of the Undulator K Parameter Using Spontaneous Radiation
نویسندگان
چکیده
Obtaining precise values of the undulator parameter, K, is critical for producing high-gain FEL radiation. At the LCLS [1], where the FEL wavelength reaches down to 1.5 Å, the relative precision of K must satisfy (ΔK/K)rms 0.015% over the full length of the undulator. Transverse misalignments, construction errors, radiation damage, and temperature variations all contribute to errors in the meanK values among the undulator segments. It is therefore important to develop some means to measure relativeK values, after installation and alignment. We propose a method using the angle-integrated spontaneous radiation spectrum of two nearby undulator segments, and the natural shot-to-shot energy jitter of the electron beam. Simulation of this scheme is presented using both ideal and measured undulator fields. By ‘leap-frogging’ to different pairs of segments with extended separations we hope to confirm or correct the values of K, including proper tapering, over the entire 130-m long LCLS undulator.
منابع مشابه
PBPL Publications: 2008-00019 PUBLICATION SPUR: A NEW CODE FOR THE CALCULATION OF SYNCHROTRON RADIATION FROM VERY LONG UNDULATOR SYSTEMS
The accurate calculation of synchrotron radiation from an undulator is a common problem and numerous codes have been developed that describe the radiation from analytic and measured undulator fields. However, for very long undulator systems there is not a suitable code that can handle the amount of data in a convenient manner and which runs in a practically realisable time limit. The developmen...
متن کاملA Prototype Phase Shifter for the Undulator Systems at the TESLA X-ray FEL
Five SASE FEL’s and five spontaneous undulator systems are proposed for the FEL lab at TESLA. The SASE systems are the longest. Their total length can be in excess of 300m. In order to keep the beam size small over the whole system a strong focusing FODO lattice is needed. The parameters for the X-ray FEL’s allow to separate between the undulators and the strong focusing. This has the advantage...
متن کاملCBN 13-1 Design and Beam Test Results of CHESS Compact Undulator
We developed, built and beam tested a novel, compact, in-vacuum undulator magnet based on an adjustable phase (AP) scheme. The undulator is 1 m long with a 5mm gap. It has a pure permanent magnet structure with 24.4mm period and 1.1 Tesla maximum peak field. The device consists of two planar magnet arrays mounted on rails inside of a rectangular box-like frame with 156 mm x 146 mm dimensions. T...
متن کاملSpur: a New Code for the Calculation of Synchrotron Radiation from Very Long Undulator Systems
The accurate calculation of synchrotron radiation from an undulator is a common problem and numerous codes have been developed that describe the radiation from analytic and measured undulator fields. However, for very long undulator systems there is not a suitable code that can handle the amount of data in a convenient manner and which runs in a practically realisable time limit. The developmen...
متن کاملAn X-Ray Absorption Edge Detector for High- Resolution Measurement of Undulator Effective K-Parameter
The spectrum of angle-integrated undulator radiation displays a sharp edge at every harmonic photon energy. A technique utilizing this feature to measure minute changes in Kparameters of an undulator in a free-electron laser has been proposed. To date, this technique requires the use of crystal monochromators as bandpass filters whose energy centroid depends on the incident angle of the x-ray b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006