Electronic cleansing in computed tomography colonography using AT layer identification with integration of gradient directional second derivative and material fraction model
نویسندگان
چکیده
BACKGROUND In computed tomography colonography images, electronic cleansing (EC) is applied to remove opacified residual materials, called fecal-tagging materials (FTM), using positive-contrast tagging agents and laxative to facilitate polyp detection. METHODS The proposed EC, EC prop , integrates the gradient directional second derivative into material fraction model to preserve submerged soft tissue (ST) under FTM. Three-material fraction model is used to remove FTM and artifacts at air-tagging (AT) layers and T-junctions where air, ST, and FTM material meet simultaneously. Moreover, the proposed AT layer identification is used to distinguish AT layers from air-tissue-tagging (ATT) layers in order to preserve ATT layers during cleansing. The clinical evaluation on 467 3-Dimensional band view images was conducted by the abdominal radiologist using four grading levels of cleansing quality with five causes of low quality EC. The amount of the remaining artifacts at T-junctions was approximated from the results of EC prop . The results from EC prop were compared with the results from syngo.via Client 3.0 Software, EC syngo , and the fast three-material modeling, EC prev , using the preference of the radiologist. Two-tailed paired Wilcoxon signed rank test is used to indicate statistical significance. RESULTS The average grade on cleansing quality is 2.89 out of 4. The artifacts at T-junctions from 86.94% of the test images can be removed, whereas artifacts at T-junctions from only 13.06% of the test images cannot be removed. For 13.06% of the test images, the results from EC prop are more preferable to the results from EC syngo (p<0.008). For all the test images, the results from EC prop are more preferable to the results from EC prev (p<0.001). Finally, the visual assessment shows that EC prop can preserve ATT layers, submerged polyps and folds while EC prev can preserve only submerged folds but fails to preserve ATT layers. CONCLUSION From our implementation, EC prop can improve the performance of the existing EC, such that it can preserve ST, especially ATT layers and remove the artifacts at T-junctions which have never been proposed by any other methods before.
منابع مشابه
A simple image processing approach for electronic cleansing in computed tomographic colonography
The prevalence of colon cancer has seen strong demand in screening for colorectal neoplasia, and this has drawn considerable attention to the technological advances in Computed Tomographic Colonography (CTC). With the assistance of an oral contrast agent, an imaging technique known as Electronic Cleansing (EC), can affect virtual cleaning of the computed tomography (CT) images, to remove fecal ...
متن کاملLesion conspicuity and efficiency of CT colonography with electronic cleansing based on a three-material transition model.
OBJECTIVE The purpose of this article is to report the effect on lesion conspicuity and the practical efficiency of electronic cleansing for CT colonography (CTC). MATERIALS AND METHODS Patients were included from the Walter Reed Army Medical Center public database. All patients had undergone extensive bowel preparation with fecal tagging. A primary 3D display method was used. For study I, th...
متن کاملThin Layer Classification for Electronic Cleansing
Thin layers of tissue and residue are easily misclassified by current electronic cleansing methods for CT colonography. Thereby holes are introduced in the colon wall that hamper visualization and automated polyp detection. We present a thin layer model to detect and characterize such layers to support electronic cleansing. It is shown that the model sustains robust estimation of the location a...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملComputed Cleansing for CT Colonography Using a Three-Material Transition Model
Virtual colonoscopy is a non-invasive technique for the detection of polyps. Currently, a clean colon is required; as without cleansing the colonic wall cannot be segmented. Enhanced bowel preparation schemes opacify intraluminal remains to enable colon segmentation. Computed cleansing (as opposed to physical cleansing of the bowels) allows removal of tagged intraluminal remains. This paper des...
متن کامل