Effect of prolonged application times on the durability of resin-dentin bonds.

نویسندگان

  • Alessandra Reis
  • Paula de Carvalho Cardoso
  • Luiz Clovis Cardoso Vieira
  • Luiz Narciso Baratieri
  • Rosa Helena Miranda Grande
  • Alessandro D Loguercio
چکیده

OBJECTIVES To examine the effect of prolonged application time on the early and 3-year resin-dentin microtensile bond strength. METHODS Water/ethanol (Single Bond [SB]) and acetone-based systems (One Step [OS]) were employed. A flat superficial dentin surface was exposed in third human molars by wet abrasion. The adhesives were applied to a delimited area of 52 mm2 on wet surfaces, for 40, 90, 150 and 300 s. Four teeth were assigned for each experimental condition. Composite build-ups were constructed incrementally. After water storage at 37 degrees C for 24 h, teeth were sectioned to obtain sticks with cross-sectional areas of 0.8 mm2 to be tested in tension (0.5 mm/min) either immediately (IM) or after 3 years (3Y) of water storage. The microtensile bond strength (microTBS) values were analyzed by two way repeated measures ANOVA and Tukey's test (alpha=0.05). RESULTS The 90- and 150-s groups achieved the highest IM microTBS for OS (p<0.01). For SB, the highest IM microTBS values were observed after 300-s application (p<0.01). Significant decreases in microTBS were observed for OS in the 40- and 90-s groups after 3Y, except for the 150-s group. With regard to SB, after 3Y significant drops in microTBS values were observed for the 40- and 150-s groups, except for the 300-s group. SIGNIFICANCE Prolonged application times can increase the immediate microTBS of two-step etch-and-rinse adhesive systems and make the adhesive layer more stable over time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Chlorhexidine Application on Bond Durability of a Filled-Adhesive System

The aim of this study was to evaluate the effect of chlorhexidine (CHX) application on immediate and two-month bond strength of a filled adhesive system. Methods: Forty eight non-carious human third molars without enamel of occlusal surface were randomly divided into two main groups according to CHX application: control and CHX. Each main group was further subdivided into 2 subgroups depending ...

متن کامل

Sodium fluoride addition to a two-step etch-and-rinse adhesive system: effect on dentin microtensile bond strength and durability

Introduction: Studies have suggested that sodium fluoride (NaF) has an inhibitory effect on the activity of endogenous matrix metalloproteinase enzymes. This study assessed the effect of a fluoride-containing adhesive on microtensile bond&nbsp;strength (&micro;TBS) over time. Material & Methods: In this experimental study, 36 extracted &nbsp;third molars were used to evaluate the &micro;TBS of...

متن کامل

Nanoleakage and Durability of Resin/Dentin Bonds

Micromorphological analysis is a useful method for the evaluation of resin–dentin bonds. Transmission electron microscopy (TEM) can also be used to analyze the structure of resin–dentin bonds because of its high resolution. There are several reasons for the degradation of resin–dentin bonds such as the activation of endogenous dentin matrix metalloproteinases and the hydrolysis of methacrylate ...

متن کامل

Effect of different synthetic matrix metalloproteinase inhibitors on composite-dentin microtensile bond strength durability

Background and Aims: Despite patient’s demand increased for tooth color restorations, the stable bond between dentin and composite is a challenge in dentistry. Dentin protease activation is responsible for dentin-resin bond failure. The aim of this study was to determine the best pretreatment agent to inhibit matrix metalloproteinase and increase resin-dentin bond durability. Materials and Met...

متن کامل

On the fatigue behavior of resin-dentin bonds after degradation by biofilm.

The durability of resin-dentin bonds is a growing concern in the placement of composite restorations. Most reported evaluations concerning the mechanical behavior of the bonded interface are conducted using static loading to failure only. They also do not account for the acid production of biofilms, which is one of the most common contributors to interfacial failures in vivo. In this investigat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dental materials : official publication of the Academy of Dental Materials

دوره 24 5  شماره 

صفحات  -

تاریخ انتشار 2008