Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy.

نویسندگان

  • V Schembri
  • B J M Heijmen
چکیده

INTRODUCTION AND PURPOSE Conventional x-ray films and radiochromic films have inherent challenges for high precision radiotherapy dosimetry. Here we have investigated basic characteristics of optically stimulated luminescence (OSL) of irradiated films containing carbon-doped aluminum oxide (Al2O3:C) for dosimetry in therapeutic photon and electron beams. MATERIALS AND METHODS The OSL films consist of a polystyrene sheet, with a top layer of a mixture of single crystals of Al2O3:C, ground into a powder, and a polyester base. The total thickness of the films is 0.3 mm. Measurements have been performed in a water equivalent phantom, using 4, 6, 10, and 18 MV photon beams, and 6-22 MeV electron beams. The studies include assessment of the film response (acquired OSL signal/delivered dose) on delivered dose (linearity), dose rate (1-6 Gy/min), beam quality, field size and depth (6 MV, ranges 4 x 4-30 x 30 cm2, dmax-35 cm). Doses have been derived from ionization chamber measurements. OSL films have also been compared with conventional x-ray and GafChromic films for dosimetry outside the high dose area, with a high proportion of low dose scattered photons. In total, 787 OSL films have been irradiated. RESULTS Overall, the OSL response for electron beams was 3.6% lower than for photon beams. Differences between the various electron beam energies were not significant. The 6 and 18 MV photon beams differed in response by 4%. No response dependencies on dose rate were observed. For the 6 MV beam, the field size and depth dependencies of the OSL response were within +/-2.5%. The observed inter-film response variation for films irradiated with the same dose varied from 1% to 3.2% (1 SD), depending on the measurement day. At a depth of 20 cm, 5 cm outside the 20 x 20 cm2 6 and 18 MV beams, an over response of 17% was observed. In contrast to GafChromic and conventional x-ray films, the response of the Al2O3:C films is linear in the clinically relevant dose range 0-200 cGy. CONCLUSIONS Measurement of the OSL signal of irradiated films containing Al2O3:C is a promising technique for film dosimetry in radiotherapy with no or small response variations with dose rate, beam quality, field size and depth, and a linear response from 0 to 200 cGy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiotherapy dosimetry using a commercial OSL system.

A commercial optically stimulated luminescence (OSL) system developed for radiation protection dosimetry by Landauer, Inc., the InLight microStar reader, was tested for dosimetry procedures in radiotherapy. The system uses carbon-doped aluminum oxide, Al2O3:C, as a radiation detector material. Using this OSL system, a percent depth dose curve for 60Co gamma radiation was measured in solid water...

متن کامل

Optically stimulated luminescence (OSL) dosimetry in irradiated alumina substrates from mobile phone resistors

In this study the dosimetric properties of alumina (Al2O3) substrates found in resistors retrieved from mobile phones were investigated. Measurements of the decline of optically stimulated luminescence (OSL) generated following exposure of these substrates to ionising radiation showed that 16% of the signal could still be detected after 2 years (735 days). Further, the magnitude of the regenera...

متن کامل

MgO:Li,Ce,Sm as a high-sensitivity material for Optically Stimulated Luminescence dosimetry.

The goal of this work was to investigate the relevant dosimetric and luminescent properties of MgO:Li3%,Ce0.03%,Sm0.03%, a newly-developed, high sensitivity Optically Stimulated Luminescence (OSL) material of low effective atomic number (Zeff = 10.8) and potential interest for medical and personal dosimetry. We characterized the thermoluminescence (TL), OSL, radioluminescence (RL), and OSL emis...

متن کامل

PTOSL response of commercial Al2O3:C detectors to ultraviolet radiation.

The photo-transferred optically stimulated luminescence (PTOSL) technique using Al2O3:C detectors has been suggested as a good option for ultraviolet (UV) radiation dosimetry. The objective of this work was to study the PTOSL response of Al2O3:C InLight detectors and the OSL microStar reader of Landauer. The parameters such as radiation pre-dose, optical treatment time and UV illumination time ...

متن کامل

Discrimination of Heavy Charged Particles in a Mixed Irradiation Using Optically Stimulated Luminescence Methods

Introduction: Astronauts are subjected to many different types of radiation. In an effort to keep track of the dose an astronaut receives, they wear dosimeters that can be read by different means. The newest method, termed Optically Stimulated Luminescence, entails using a known wavelength of light to stimulate the dosimeter material causing it to emit light of a different wavelength. By measur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 34 6  شماره 

صفحات  -

تاریخ انتشار 2007