Improving the measurement of longitudinal change in renal function: automated detection of changes in laboratory creatinine assay.

نویسندگان

  • Norman Poh
  • Andrew Peter McGovern
  • Simon de Lusignan
چکیده

INTRODUCTION Renal function is reported using the estimates of glomerular filtration rate (eGFR). However, eGFR values are recorded without reference to the particular serum creatinine (SCr) assays used to derive them, and newer assays were introduced at different time points across the laboratories in the United Kingdom. These changes may cause systematic bias in eGFR reported in routinely collected data, even though laboratory-reported eGFR values have a correction factor applied. DESIGN An algorithm to detect changes in SCr that in turn affect eGFR calculation method was developed. It compares the mapping of SCr values on to eGFR values across a time series of paired eGFR and SCr measurements. SETTING Routinely collected primary care data from 20,000 people with the richest renal function data from the quality improvement in chronic kidney disease trial. RESULTS The algorithm identified a change in eGFR calculation method in 114 (90%) of the 127 included practices. This change was identified in 4736 (23.7%) patient time series analysed. This change in calibration method was found to cause a significant step change in the reported eGFR values, producing a systematic bias. The eGFR values could not be recalibrated by applying the Modification of Diet in Renal Disease equation to the laboratory reported SCr values. CONCLUSIONS This algorithm can identify laboratory changes in eGFR calculation methods and changes in SCr assay. Failure to account for these changes may misconstrue renal function changes over time. Researchers using routine eGFR data should account for these effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Towards automated identification of changes in laboratory measurement of renal function: implications for longitudinal research and observing trends in glomerular filtration rate (GFR)

Introduction: Kidney function is reported using estimates of glomerular filtration rate (eGFR). However, eGFR values are recorded without reference to the creatinine (SCr) assays used to derive them, and newer assays were introduced at different time points across laboratories in UK. These changes may cause systematic bias in eGFR reported in routinely collected data; even though laboratory rep...

متن کامل

Comparative Assessment of Neutrophil Gelatinase-Associated Lipocalin (NGAL) and Cystatin C as Early Biomarkers for Early Detection of Renal Failure in Patients with Hypertension

Background: Hypertension is one the most common causes of chronic kidney disease (CKD). One of the major concerns in hypertensive patients is early detection of renal disorders. In the past, serum creatinine (Scr) concentration was used as a marker of kidney function, but it proffers a late reflection of reduced glomerular filtration rate. Cystatin C and neutrophil gelatinase-associated lipocal...

متن کامل

Concept drift detection in business process logs using deep learning

Process mining provides a bridge between process modeling and analysis on the one hand and data mining on the other hand. Process mining aims at discovering, monitoring, and improving real processes by extracting knowledge from event logs. However, as most business processes change over time (e.g. the effects of new legislation, seasonal effects and etc.), traditional process mining techniques ...

متن کامل

Comparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation

Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...

متن کامل

مطالعه سیستاتین C سرم و کراتینین سرم به عنوان شاخص مطمئن در تشخیص نارسایی کلیوی بیماران فشار خونی

    Background & Aims : In the past serum creatinine concentration was used as one of the important markers for early detection of kidney disorders, however recent studies suggest serum cystatin C to be a better marker. Therefore in this study we compared the diagnostic value of cystatin C with serum creatinine to evaluate kidney function in patients with high blood pressure.   Materials & Meth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of innovation in health informatics

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2015