The tourniquet in total knee arthroplasty. A prospective, randomised study.
نویسندگان
چکیده
We assessed the influence of the use of a tourniquet in total knee arthroplasty in a prospective, randomised study. After satisfying exclusion criteria, we divided 77 patients into two groups, one to undergo surgery with a tourniquet and one without. Both groups were well matched. The mean change in knee flexion in the group that had surgery without a tourniquet was significantly better at one week (p = 0.03) than in the other group, but movement was similar at six weeks and at four months. There was no significant difference in the surgical time, postoperative pain, need for analgesia, the volume collected in the drains, postoperative swelling, and the incidence of wound complications or of deep-venous thrombosis. We conclude that the use of a tourniquet is safe and that current practice can be continued.
منابع مشابه
Effects of Tourniquet Use on Quadriceps Function and Pain in Total Knee Arthroplasty
PURPOSE A pneumatic tourniquet is commonly used in total knee arthroplasty (TKA) to improve surgical field visualisation but may result in quadriceps muscle ischaemia. We performed this study to analyse the effect of the tourniquet on recovery following TKA. MATERIALS AND METHODS A prospective randomised single-blinded trial was undertaken to examine the effect of the tourniquet on post-opera...
متن کاملInfluence of tourniquet use in primary total knee arthroplasty with drainage: a prospective randomised controlled trial
BACKGROUND We aimed to compare the effect of tourniquet use or lack of it on recovery following uncomplicated primary total knee arthroplasty (TKA). METHODS In a prospective randomised double-blinded study, 150 patients undergoing primary TKA were assigned to either a tourniquet or non-tourniquet group. At the early phase, 3 and 6 months after surgery, an independent observer assessed the pri...
متن کاملDelayed release of drain in total knee replacement reduces blood loss. A prospective randomised study.
Total knee arthroplasty is sometimes associated with major post-operative bleeding, often requiring transfusion. A prospective, randomised study was undertaken to assess the effect on post-operative bleeding of delaying release of the clamp on the suction drains. One hundred patients were allocated into two groups: Group A- immediate release of drain following release of tourniquet, and Group B...
متن کاملAbnormal echogenic findings detected by transesophageal echocardiography and cardiorespiratory impairment during total knee arthroplasty with tourniquet.
BACKGROUND In patients undergoing total knee arthroplasty, intraoperative pulmonary embolic events are rare, and most occur following tourniquet deflation. This embolization can be observed using transesophageal echocardiography. However, the authors have encountered sudden decreases in arterial oxygen partial pressure while a tourniquet is still inflated. Therefore, the current investigation w...
متن کاملThe influence of tourniquet use and timing of its release on blood loss in total knee arthroplasty.
In surgical practice, hemostasis is used to minimize postoperative bleeding in total knee arthroplasty. We performed a prospective randomized study to determine the influence of tourniquet use and the timing of its release on amount of bleeding. Eighty four patients (96 knees) were scheduled for total knee arthroplasty and randomly divided into three groups. Posterior cruciate retaining bicompa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 81 1 شماره
صفحات -
تاریخ انتشار 1999