Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering

نویسندگان

  • Jyotsna James
  • Lokesh Tiwari
  • Pramod Upadhyay
  • Vishnubhatla Sreenivas
  • Vikas Bhambhani
  • Jacob M Puliyel
چکیده

BACKGROUND The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. METHODS POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. RESULTS The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. CONCLUSION Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns

Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...

متن کامل

Comparative study of pulse oximetry, physical examination and echocardiography results in the diagnosis of congenital heart defects in neonates in the first 24 hours of life

Introduction: Congenital heart disease is the most common congenital anomaly. About 50% of Neonates with congenital heart disease are asymptomatic in the first few days of life and are not diagnosed on initial examination. Pulse oximetry is a non-invasive method that can show the percentage of oxygen saturation in the blood and congenital heart disease. Methods: This was a descriptive cross-se...

متن کامل

Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry.

Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible influences of dyshaemoglobins and fetal haemoglobin on the accuracy of pulse oximetry are discussed. As ...

متن کامل

A Comparison of Arterial Oxygen Saturation Measured Both by Pulse Oximeter and Arterial Blood Gas Analyzer in Hypoxemic and Non-hypoxemic Pulmonary Diseases

INTRODUCTION Pulse oximetry is a useful tool for clinical and investigational purposes for indirect measurements of oxygen saturation [1-3]. Measurement of oxygen saturation with pulse oximetry (SpO2) can be used for evaluation and control of hypoxemia in chronic obstructive pulmonary disease (COPD). As pulse oximetry is a non–invasive device, it can be used instead of arterial blood gases (ABG...

متن کامل

Pulse Oximetry Screening to Detect Cyanotic Congenital Heart Disease in Sick Neonates in a Neonatal Intensive Care Unit.

OBJECTIVE To evaluate pulse oximetry for detection of congenital cyanotic heart disease in sick neonates using echocardiography as gold standard. METHODS Pulse oximetry readings were taken at admission from 950 neonates from right upper limb and either foot with infant breathing room air. Pulse oximetry was considered abnormal if oxygen saturation at room air measured <90% or difference betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BMC Pediatrics

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2006