A method for routine analysis of urinary 4,4'-methylenebis (2-chloroaniline) by gas chromatography-electron capture detection.

نویسندگان

  • Akito Takeuchi
  • Akira Namera
  • Norihiro Sakui
  • Kenji Yamamuro
  • Toshio Kawai
  • Kimiaki Sumino
چکیده

OBJECTIVES The purpose of this study was to develop a simple and cost-effective method for the determination of urinary 4,4'-methylenebis (2-chloroaniline) (MBOCA) by gas chromatography-electron capture detection (GC-ECD) for biological monitoring of occupational exposure to MBOCA. METHODS MBOCA was prepared by liquid-liquid extraction after alkaline hydrolysis, derivatized with N-methyl-bis (trifluoroacetamide) and then analyzed using GC-ECD. The proposed method was validated in accordance with the US Food and Drug Administration guidance. RESULTS The calibration curve showed linearity in the range 1-100 µg/l, with a correlation coefficient of >0.999. The limits of detection and quantification were 0.3 µg/l and 1 µg/l, respectively. The recovery was 94-99%. Intraday accuracy, expressed as the deviation from the nominal value, was 90.5-100.3%, and intraday precision, expressed as the relative standard deviation, was 0.3-2.4%. Interday accuracy and precision were 87.8-100.2% and 0.3-4.1%, respectively. CONCLUSIONS The proposed method is a simple and cost-effective method suitable for routine analyses and could be useful for biological monitoring of occupational exposure to MBOCA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of 4,4'-methylenebis(2-chloroaniline) in urine by liquid chromatography with ion-paired solid-phase extraction and electrochemical detection.

This highly specific and sensitive method for measuring urinary 4,4'-methylenebis(2-chloroaniline) (MBOCA) involves liquid chromatography with electrochemical detection. Before chromatography, urine samples are prepared by ion-paired solid-phase extraction on a disposable octadecylsilica column with acidic methanol solution containing 1-heptanesulfonic acid. This enhances the specificity of the...

متن کامل

Determination of 4,4'-methylenebis(2-chloroaniline) in urine.

We read with interest the paper by Okayania et al. (1) describing a liquidchromatographic method for measuring 4,4’-methylenebis(2-chloroaniline) (MB0CA) in urine by use of solid-phase extraction and electrochemical detection. For over 10 years we have been involved in the routine monitoring of workers who are exposed to MBOCA. We do this by measuring MBOCA in the urine (2). Initially, we used ...

متن کامل

Biological monitoring of workers exposed to 4,4'-methylenebis (2-chloroaniline) (MBOCA).

A biological monitoring programme has been developed for assessing occupational exposure to 4,4'-methylenebis (2-chloroaniline) (MBOCA) in a factory which manufactures polyurethane elastomers. In a systematic programme of biological monitoring over a five year period urinary MBOCA concentrations have been used to provide evidence of absorption of MBOCA. Improvements in the handling and use of M...

متن کامل

Monitoring exposure to 4,4'-methylene-bis(2-chloroaniline) through the gas chromatography-mass spectrometry measurement of adducts to hemoglobin.

4,4'-Methylene-bis(2-chloroaniline) (MOCA) is widely used as a curing agent in the plastics industry. The determination of the covalently bound reaction products to hemoglobin (Hb) has been investigated as a biomonitoring method for occupational exposure to this potential human carcinogen. Initial studies using the 14C-ring-labeled MOCA showed that 24 hr after a single IP dosage to rats (3.74 m...

متن کامل

Absorption of 4,4'-methylenebis [2-chloroaniline] by human skin.

A system was developed to measure percutaneous absorption of water-insoluble environmental agents into human skin. Percutaneous absorption of 4,4'-[14C]methylenebis [2-chloroaniline] (MBOCA) was measured during dry contact exposure of MBOCA with organ cultures of neonatal foreskin. Time-dependent exposures, autoradiographs, and thin-layer chromatography indicated that MBOCA was rapidly and prog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of occupational health

دوره 56 5  شماره 

صفحات  -

تاریخ انتشار 2014