Determination of Force Coresponding to Maximal Lactate Steady State in Tethered Swimming

نویسندگان

  • MARCELO PAPOTI
  • RICARDO VITÓRIO
  • GUSTAVO G. ARAÚJO
  • ADELINO S. R. DA SILVA
  • VANESSA SANTHIAGO
  • LUIZ E. B. MARTINS
  • SÉRGIO A. CUNHA
  • CLAUDIO A. GOBATTO
چکیده

The main aim of the present investigation was to verify if the aerobic capacity (AC) measured in tethered swimming corresponds to the maximal lactate steady state (MLSS) and its correlation with 30 min and 400m free style swimming. Twenty-five swimmers were submitted to an incremental tethered swimming test (ITS) with an initial load of 20N and increments of 10N each 3min. After each stage of 3min, the athletes had 30s of interval to blood sample collections that were used to measure blood lactate concentrations ([La-]). The ACBI was determined by the abrupt increase in [La-] versus force (F). The points obtained between [La-] versus force (N) were adjusted by an exponential curve model to determine AC corresponding to 3.5mmol.l-1 (AC3.5) and 4.0mmol.l-1 (AC4.0). After these procedures, the swimmers performed maximal efforts of 30min and 400m in free style swimming. We used the distance performed in 30min and the time performed in 400m to calculate the median velocities (i.e. V30 and V400) of these protocols. After one week, in order to measure the MLSS, nine athletes performed three 30-min tethered swimming efforts with intensities of 90, 100, and 110% of ACBI. The ANOVA one-way was used to compare the ACBI, AC3.5 and AC4.0. Correlations between ACs, and between ACs and V30 and V400 (p<0.05) were determined using the Pearson's correlation coefficient. The intensity corresponding to 100% of ACBI was similar to the MLSS. It was observed significant correlations of the aerobic capacities (i.e. ACBI, AC3.5 and AC4.0) with V30 (r>0.91) and V400 (r>0.63). According to our results, it is possible to conclude that the ACBI corresponds to the MLSS, and both the AC - individually determined - and the AC - determined using fixed blood lactate concentrations of 3.5 and 4.0mmol.l-1 - can be used to predict the mean velocity of 30min and 400m in free style swimming. In addition to that, the tethered swimming system can be used for aerobic development in places where official sized swimming pools are not available, such as rehabilitation clinics and health clubs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of pool length on blood lactate, heart rate, and velocity in swimming.

Exercise testing in water has been used to follow the progression of conditioning during regular training in swimmers. The present study examined the effects of pool length in eleven male swimmers on a set of 5 x 200-m freestyle swims with increasing speed from submaximal to maximal. Mean velocity of swimming, blood lactate and heart rate were examined in both 25-m and 50-m pools. Turning benef...

متن کامل

Effect of the Fast-Skin swim suit on Iranian elite female swimmers' performance

The purpose of this investigation was to consider the Fast-Skin swimsuit's effect on the elite female swimmers’ performance. So, twelve elite swimmers swam 50 and 200 m and 400 m trials with and without Fast-Skin at approximately 80- 100% of maximal effort in four swimming styles. In 400 m freestyle swimming, traditional swimsuit compared with shoulder-to-ankle (SA) and shoulder-to-knee (S...

متن کامل

Aerobic and anaerobic performances in tethered swimming.

The purpose of this study was to investigate whether the critical force (CritF) and anaerobic impulse capacity (AIC) - estimated by tethered swimming - reflect the aerobic and anaerobic performance of swimmers. 12 swimmers performed incremental test in tethered swimming to determine lactate anaerobic threshold (AnTLAC), maximal oxygen uptake ( ˙VO2MAX) and force associated with the ˙VO2MAX (i ˙...

متن کامل

Reliability of Tethered Swimming Evaluation in Age Group Swimmers

The aim of the present study was to examine the reliability of tethered swimming in the evaluation of age group swimmers. The sample was composed of 8 male national level swimmers with at least 4 years of experience in competitive swimming. Each swimmer performed two 30 second maximal intensity tethered swimming tests, on separate days. Individual force-time curves were registered to assess max...

متن کامل

Quantification of Maximal Force Produced in Standard and Contra- Standard Sculling in Synchronized Swimming. A Pilot Study

Studies carried out in synchronized swimming are very scarce, namely those which include biomechanical analysis of the sculling technique. The purpose of this study was to measure the maximal force produced in standard and contra-standard sculling, using a 30s maximal tethered synchronized swimming test. One former female synchronized swimmer and one former female swimmer performed a 2x30s maxi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2009