PULSAR: A MATLAB Toolbox for Parallel Magnetic Resonance Imaging Using Array Coils and Multiple Channel Receivers

نویسندگان

  • JIM X. JI
  • JONG BUM SON
  • SWATI D. RANE
چکیده

Partial parallel imaging (PPI) techniques using array coils and multichannel receivers have become an effective approach to achieving fast magnetic resonance imaging (MRI). This article presents a Matlab toolbox called PULSAR (Parallel imaging Utilizing Localized Surface-coil Acquisition and Reconstruction) that can simulate the data acquisition and image reconstruction, and analyze performance of five common PPI techniques. PULSAR can simulate sensitivity functions of rectangular loop coils using a quasi-static model based on Biot-Savart’s Law and undersampled multichannel data acquisition on a rectilinear k-space grid. In addition, PULSAR provides performance evaluation of the techniques based on artifact power (AP), signal-to-noise ratio (SNR), and computational complexity. In this article, the structure and functionality of the PULSAR toolbox are described. Examples using both the simulated and real four-channel and eight-channel data were used to demonstrate the utilities of the toolbox and to show that PULSAR is a convenient and effective means to study the PPI under different coil geometries, acquisition strategies, and reconstruction methods. © 2007 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 31B: 24–36, 2007

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Numerical Evaluation of an 8-element Phased Array Torso Coil for Magnetic Resonance Imaging

Recently, parallel imaging using multiple RF coils has excited great interest in magnetic resonance imaging (MRI). To help the design of some novel flexible array coils for the human torso, we theoretically investigate the RF field of an 8-element array coil loaded with an anatomically accurate model of the human torso. The RF behaviour is predicted based on a hybrid FDTD/MoM approach. The prim...

متن کامل

Magnetic resonance imaging (MRI) and spectroscopy (MRS) using simultaneous 2-channel acquisitions: Application for mouse brain examination by reconfiguration of a "standard" Bruker spectrometer

In the field of small animal imaging, the interest for phased array coil imaging is growing but high field MR experimental systems with multiple receiver channels are still rare and the upgrade of existing systems is relatively expensive. In this work, a standard 4.7 T Bruker Biospec Avance II spectrometer was modified to allow simultaneous two-channel acquisitions. Modifications were validated...

متن کامل

Resonance Shift Decoupling: A Potential Alternative to Low Input Impedance Preamplifiers

Introduction The use of phased-array coils has become desirable for efficient magnetic resonance imaging in both clinical and preclinical biological investigations. Multi-channel receivers are now commonplace, allowing the use of phased-array coils with many elements. Coupling becomes increasingly problematic with more elements, degrading the independence of coil sensitivities required for para...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007