Maximum likelihood autocalibration
نویسندگان
چکیده
This paper addresses the problem of autocalibration, which is a critical step in existing uncalibrated structure from motion algorithms that utilize an initialization to avoid the local minima in metric bundle adjustment. Currently, all known direct (not non-linear) solutions to the uncalibrated structure from motion problem solve for a projective reconstruction that is related to metric by some unknown homography, and hence a necessary step in obtaining a metric reconstruction is the subsequent estimation of the rectifying homography, known as autocalibration. Although autocalibration is a well-studied problem, previous approaches have relied upon heuristic objective functions, and have a reputation for instability. We propose a maximum likelihood objective and show that it can be implemented robustly and efficiently, and often provides substantially greater accuracy, especially when there are fewer views or greater noise.
منابع مشابه
Autocalibration in hydrologic modeling: Using SWAT2005 in small-scale watersheds
SWAT is a physically based model that can simulate water quality and quantity at the watershed scale. Due to many of the processes involved in the manualor autocalibration of model parameters and the knowledge of realistic input values, calibration can become difficult. An autocalibration-sensitivity analysis procedure was embedded in SWAT version 2005 (SWAT2005) to optimize parameter processin...
متن کاملAutocalibration of an electronic compass in an outdoor augmented reality system
Accurate registration in an Augmented Reality system requires accurate trackers. An electronic compass can be a valuable sensor in an outdoor Augmented Reality system because it provides absolute heading estimates. However, compasses are vulnerable to distortion caused by environmental disturbances to Earth’s magnetic field. These disturbances vary with geographic location and are not trivial t...
متن کاملOn-line controller autocalibration based on parameter predictors: a case study
In this paper, a method for the on-line autocalibration of a controller, based on statistical regression techniques, is presented. The control of neuromuscular blockade is used as a case study. The method relies on the information about the patients dynamics, inferred from the response induced by the initial bolus dose given in the beginning of anaesthesia. A new approach to the characterizatio...
متن کاملAutocalibration of accelerometer data for free-living physical activity assessment using local gravity and temperature: an evaluation on four continents
Wearable acceleration sensors are increasingly used for the assessment of free-living physical activity. Acceleration sensor calibration is a potential source of error. This study aims to describe and evaluate an autocalibration method to minimize calibration error using segments within the free-living records (no extra experiments needed). The autocalibration method entailed the extraction of ...
متن کاملSome Improvements on Two Autocalibration Algorithms Based on the Fundamental Matrix
Autocalibration algorithms based on the fundamental matrix must solve the problem of finding the global minimum of a cost function which has many local minima. We describe a new method of achieving this goal, which uses a stochastic optimization approach taken from the field of evolutionary algorithms. In theory, approaches that use the fundamental matrix for autocalibration are inferior to tho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Image Vision Comput.
دوره 29 شماره
صفحات -
تاریخ انتشار 2011