Islet Autoantibody Measurements from Dried Blood Spots on Filter Paper Strongly Correlate to Serum Levels

نویسندگان

  • Kimber M. Simmons
  • Aimon K. Alkanani
  • Kristen A. McDaniel
  • Christopher Goyne
  • Dongmei Miao
  • Zhiyuan Zhao
  • Liping Yu
  • Aaron W. Michels
چکیده

Type 1 diabetes (T1D) is increasing in incidence and predictable with measurement of serum islet autoantibodies (iAb) years prior to clinical disease onset. Identifying iAb positive individuals reduces diabetic ketoacidosis and identifies individuals for T1D prevention trials. However, large scale screening for iAb remains challenging as assays have varying sensitivities and specificities, insulin autoantibodies remain difficult to measure and venipuncture is generally required to obtain serum. We developed an approach to reliably measure all four major iAb, including insulin autoantibodies, from dried blood spots (DBS) on filter-paper. By spiking iAb positive serum into iAb negative whole blood in a dose titration, we optimized the conditions for autoantibody elution from filter paper as measured by fluid phase radioimmunoassays. After assessing stability of measuring iAb from DBS over time, we then screened iAb from DBS and the corresponding serum in new-onset T1D (n = 52), and controls (n = 72) which included first-degree relatives of T1D patients. iAb measured from eluted DBS in new-onset T1D strongly correlated with serum measurements (R2 = 0.96 for mIAA, GADA = 0.94, IA-2A = 0.85, ZnT8A = 0.82, p<0.01 for each autoantibody). There were no false positives in control subjects, and 5/6 with previously unknown iAb positivity in sera were detected using DBS. With further validation, measuring iAb from DBS can be a reliable method to screen for T1D risk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radioimmunoassay of "free thyroxin" in dried blood spots on filter paper - preliminary observations on the effective differentiation of subjects with congenital hypothyroidism from those with subnormal thyroxin-binding globulin and normal subjects.

In this sensitive, simple method for measuring "free thyroxin" (FT4) in eluates of dried blood spots on filter paper by use of a radioimmunoassay kit (Amerlex Free T4 RIA), the measurable range of FT4 is 1.8 to 57 ng/L (equivalent to the concentration in serum), or 7 to 237 fg/tube. The mean coefficients of variation for within assay-within spots, within assay-between spots, and between assays ...

متن کامل

Micromethod for estimating adenosine deaminase activity in dried blood spots on filter paper.

We describe a fluorometric micromethod for measuring adenosine deaminase activity in dried blood spots on filter paper. Earlier methods require venipuncture and preparation of washed erythrocytes; in the present method, whole capillary blood, spotted on filter paper and mailed (dried) to a central laboratory, is used. The stability of the enzyme in dried blood on filter paper was assessed. The ...

متن کامل

Use of dried spots of whole blood, plasma, and mother's milk collected on filter paper for measurement of human immunodeficiency virus type 1 burden.

We studied the use of dried spots of bodily fluids (plasma, whole blood, and mother's milk) on filter paper as a means of sample collection and storage for human immunodeficiency virus type 1 (HIV-1) viral load testing under stringent field conditions. Plasma placed directly in lysis buffer, which is customarily used for viral load assays, was used for comparison in all our experiments. Utilizi...

متن کامل

Direct solid-phase time-resolved fluoroimmunoassay of 17 alpha-hydroxyprogesterone in serum and dried blood spots on filter paper.

We describe a direct, solid-phase time-resolved fluoroimmunoassay (TRFIA) for measuring 17 alpha-hydroxyprogesterone (17OHP) in serum and blood spots on filter paper. We used 17OHP-3-carboxymethyloxime (17OHP3CMO) coupled to polylysine as the label, which enabled incorporation of up to 34 atoms of europium per molecule of 17OHP, for a very high specific activity. The assay is based on competiti...

متن کامل

Rapid DNA Extraction from Dried Blood Spots on Filter Paper: Potential Applications in Biobanking

OBJECTIVES Dried blood spot (DBS) technology is a microsampling alternative to traditional plasma or serum sampling for pharmaco- or toxicokinetic evaluation. DBS technology has been applied to diagnostic screening in drug discovery, nonclinical, and clinical settings. We have developed an improved elution protocol involving boiling of blood spots dried on Whatman filter paper. METHODS The pu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016