Rabbit and monkey visual cortex: more than a year of recording with up to 64 microelectrodes.
نویسندگان
چکیده
In the visual cortex of rabbits and a marmoset monkey, 32 and 64 microwires, respectively, were chronically implanted by an indirect insertion method so that the cortex was penetrated from the white matter. For more than 1 year recordings of action potentials of good quality were obtained at most electrodes. Recording stability was judged by spike shape, spike train autocorrelograms, and spike rates: within recording sessions, stability was essentially perfect. Periods in which the signals of several electrodes were stable could last for several days. A method of in vivo reconstruction of the electrode locations by micro-X-rays and subsequent stereophotogrammetry is presented. The aspect of animal welfare is considered.
منابع مشابه
Seven Years of Recording from Monkey Cortex with a Chronically Implanted Multiple Microelectrode
A brush of 64 microwires was chronically implanted in the ventral premotor cortex of a macaque monkey. Contrary to common approaches, the wires were inserted from the white matter side. This approach, by avoiding mechanical pressure on the dura and pia mater during penetration, disturbed only minimally the cortical recording site. With this approach isolated potentials and multiunit activity we...
متن کاملA new type of recording chamber with an easy-to-exchange microdrive array for chronic recordings in macaque monkeys.
In monkeys, long-term recordings with chronically implanted microelectrodes frequently suffer from a continuously decreasing probability to record single units or even small multiunit clusters. This problem is associated with two technical limitations of the available devices: first, restrictions for electrode movement, and second, absent possibility to exchange electrodes easily on a regular b...
متن کاملInnovative Methodology A new type of recording chamber with an easy-to-exchange microdrive array for chronic recordings in macaque monkeys
Galashan FO, Rempel HC, Meyer A, Gruber-Dujardin E, Kreiter AK, Wegener D. A new type of recording chamber with an easy-to-exchange microdrive array for chronic recordings in macaque monkeys. J Neurophysiol 105: 3092–3105, 2011. First published March 30, 2011; doi:10.1152/jn.00508.2010.—In monkeys, long-term recordings with chronically implanted microelectrodes frequently suffer from a continuo...
متن کاملA new planar multielectrode array: recording from a rat auditory cortex.
In the study of the spatiotemporal properties of the cortex, a demand often arises for recording local field evoked potentials (LFEP) and neural spikes from a quantity of points at close range from each other. In such a situation a device composed of a lot of electrodes assembled in a single bunch would be suitable. Such circumstances gave us the impetus to create the device described in this p...
متن کاملChronic neural probe for simultaneous recording of single-unit, multi-unit, and local field potential activity from multiple brain sites.
OBJECTIVE Drug resistant focal epilepsy can be treated by resecting the epileptic focus requiring a precise focus localisation using stereoelectroencephalography (SEEG) probes. As commercial SEEG probes offer only a limited spatial resolution, probes of higher channel count and design freedom enabling the incorporation of macro and microelectrodes would help increasing spatial resolution and th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neuroscience methods
دوره 95 1 شماره
صفحات -
تاریخ انتشار 2000