Effect of Perforated Plate Open Area on Gas Holdup in Rayon Fiber Suspensions
نویسندگان
چکیده
Three different aeration plates are used to study their effect on gas holdup and flow regime transition in fiber suspensions. The aeration plates differ by their open-area ratios (A=0.57%, 0.99%, and 2.14%), where the hole diameter remains the same while the number of holes increase. Experiments are performed using three different Rayon fiber lengths (L=3, 6, and 12mm) over a range of superficial gas velocities (Ug⩽18cm/s) and fiber mass fractions (0⩽C⩽1.8%) in a 15.24cm dia semi-batch bubble column. Experimental results show that the aeration plate with A=0.99% produces the highest gas holdup in an air-water system and low fiber mass fraction suspensions, and the plate with A=2.14% yields the lowest gas holdup in these systems. In medium fiber mass fraction suspensions, the plate with A=0.57% produces slightly higher gas holdup values, while the other two plates yield similar results. The effect of the aeration plate open area on gas holdup diminishes at high fiber mass fractions (C⩾1.2%). All aeration plates generate homogeneous, transitional, and heterogeneous flow regimes over the range of superficial gas velocities for air-water and low fiber mass fraction suspensions. However, the aeration plate with A=2.14% enhances the flow regime transition, i.e., the superficial gas velocity at which transitional flow appears is lower. Additionally, the fiber mass fraction at which pure heterogeneous flow is observed is lower when A=2.14%. Disciplines Complex Fluids | Mechanical Engineering | Thermodynamics Comments This article is from Journal of Fluids Engineering 12 (2005): 816–823, doi:10.1115/1.1994878. Posted with permission. This article is available at Iowa State University Digital Repository: http://lib.dr.iastate.edu/me_pubs/17
منابع مشابه
Gas holdup in a gas-liquid-fiber semi-batch bubble column
A 4-m high, 15.24-cm diameter semi-batch bubble column connected to one of three perforated plate gas distributors with open area ratios A = 0.57%, 0.99%, and 2.14% is employed to study gas holdup and flow regime in Rayon and Nylon fiber suspensions. This study determines the effect of superficial gas velocity, fiber type, fiber mass fraction, fiber length, and aeration plate open area ratio on...
متن کاملGas Holdup Behavior in Nylon Fiber Suspensions
The gas holdup behavior in a nylon fiber suspension with various fiber lengths (L = 2, 3, and 6 mm) is investigated. Experiments are performed over a range of superficial gas velocities (Ug≤ 18 cm/s) and a range of fiber mass fractions (0 ≤ C ≤ 1.8%) in a 15.24-cm-diameter semibatch bubble column. Day-to-day variations in the gas holdup create difficulties in interpreting the effect of the fibe...
متن کاملEulerian simulation of bubble columns reactors and effect of various parameters on the gas holdup
Gas holdup and bubble size are important parameters for simulation and designing in bubble column reactors. Because based on these parameters, the available gas-liquid interfacial area is defined for mass transfer. In this paper, the results of applying magnetic fields on the velocity field and volume fraction of gas holdup are reported. Hydrodynamics of the bubble column in the reactors is inv...
متن کاملEffect of viscosity on homogeneous–heterogeneous flow regime transition in bubble columns
Experiments were performed in a cylindrical 0.14 m diameter bubble column with a metal perforated plate. Air and aqueous solutions of glycerol with viscosity 1–22 mPa s were the phases. Gas holdup was measured and plotted against the gas flow rate. The critical point where the homogeneous–heterogeneous regime transition begins was determined by the drift-flux plot of the primary data. The homog...
متن کاملStudy on Mass Transfer Enhancement in a Gas-Liquid System Using Nanomaterials
The main objective of this paper is to examine the effect of nanomaterials on mass transfer coefficient in bubble type absorption of carbon dioxide by experiment. The absorption process is carried out in a bubble column and in room temperature. Mass transfer coefficient, saturated concentration of CO2, and gas holdup are determined in this system. The kinds of nanomaterials, the concentrations ...
متن کامل