Exoseal for puncture site closure after antegrade procedures in peripheral arterial disease patients.

نویسندگان

  • Gerald Hackl
  • Thomas Gary
  • Klara Belaj
  • Franz Hafner
  • Peter Rief
  • Hannes Deutschmann
  • Marianne Brodmann
چکیده

PURPOSE Exoseal is a vascular clo-sure device consisting of a plug applier and a bio-absorbent polyglycolic acid plug available in sizes 5 F, 6 F, and 7 F. In this study, we aimed to evaluate the effectiveness and safety of the Exoseal vascular closure device (Cordis Corporation, Bridgewater, New Jersey, USA) for puncture site closure after antegrade endovascular procedures in peripheral arterial occlusive disease (PAOD) patients. MATERIALS AND METHODS In this retrospective study, a total of 168 consecutive patients who underwent an interventional procedure due to PAOD, were included. In each case, an antegrade peripheral endovascular procedure was performed via the common femoral artery using the Seldinger technique, and Exoseal 5 F, 6 F, or 7 F was used for access site closure. The primary endpoint was a technically successful application of Exoseal. All complications at the access site within 24 hours were registered as a secondary endpoint. RESULTS In a group of 168 patients (64.9% men, average age 71.9±11.9 years), the technical application of Exoseal was successful in 166 patients (98.8%). Within the first 24 hours after the procedure, 12 complications (7.2%) were recorded including, three pseudoaneurysms (1.8%) and nine hematomas (5.4%). None of the complications required surgical intervention. CONCLUSION Exoseal is a safe and effective device with high technical success and acceptable complication rates for access site closure after antegrade peripheral endovascular procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Vascular Closure System Based on an Extravascular, Bioabsorbable Polyglycolic Plug (ExoSeal): Results from 1000 Patients

PURPOSE The objective of this prospective study was to evaluate the effectiveness and safety of a percutaneous closure system based on a polyglycolic acid plug for achieving hemostasis. MATERIAL AND METHODS In this study from 2011 to 2014, a percutaneous vascular closure system (ExoSeal) was used in 1000 patients (mean age 70.6 ± 10.2 years), using antegrade and retrograde techniques within t...

متن کامل

Twelve months follow-up after retrograde recanalization of superficial femoral artery chronic total occlusion

INTRODUCTION Fifty percent of cases of peripheral artery disease are caused by chronic total occlusion (CTO) of the superficial femoral artery (SFA). Ten-fifteen percent of percutaneous SFA recanalization procedures are unsuccessful. In those cases the retrograde technique can increase the success rate of the procedure, but the long-term follow-up of such procedures is still unknown. AIM To a...

متن کامل

Starclose SE® hemostasis after 6F direct antegrade superficial femoral artery access distal to the femoral head for peripheral endovascular procedures in obese patients.

PURPOSE Direct superficial femoral artery (SFA) antegrade puncture is a valid alternative to common femoral artery (CFA) access for peripheral vascular interventions. Data investigating vascular closure device (VCD) hemostasis of distant SFA 6F access are limited. We aimed to investigate the safety and effectiveness of the Starclose SE® VCD for hemostasis, following direct 6F antegrade SFA acce...

متن کامل

Percutaneous retrograde transfemoral closure of mitral paravalvular leak in 3 patients without construction of an arteriovenous wire loop.

Percutaneous closure of paravalvular leaks has emerged as an alternative to repeated surgeries. Different percutaneous techniques and various devices have been used, off-label, for paravalvular leak closure. For mitral leaks, antegrade transseptal, retrograde transfemoral, and retrograde transapical techniques have been developed. In the antegrade transseptal approach, an arteriovenous guidewir...

متن کامل

A Modified Technique to Safely Close the Arterial Puncture Site After TAVI.

BACKGROUND We describe a vascular closure technique, convenient in practice, that permits effective femoral artery closure after CoreValve (Medtronic) implantation during transcatheter aortic valve implantation (TAVI). Vascular complications of transfemoral access implantation have been associated with significantly increased patient morbidity and mortality, as well as with increased hospitaliz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 20 5  شماره 

صفحات  -

تاریخ انتشار 2014