Radiotherapy Current Awareness Bulletin January 2017
نویسنده
چکیده
To quantify the performance of the Clarity ultrasound (US) imaging system (Elekta AB, Stockholm, Sweden) for real-time dynamic multileaf collimator (MLC) tracking. The Clarity calibration and quality assurance phantom was mounted on a motion platform moving with a periodic sine wave trajectory. The detected position of a 30 mm hypoechogenic sphere within the phantom was continuously reported via Clarity's real-time streaming interface to an in-house tracking and delivery software and subsequently used to adapt the MLC aperture. A portal imager measured MV treatment field/MLC apertures and motion platform positions throughout each experiment to independently quantify system latency and geometric error. Based on the measured range of latency values, a prostate stereotactic body radiation therapy (SBRT) delivery was performed with three realistic motion trajectories. The dosimetric impact of system latency on MLC tracking was directly measured using a 3D dosimeter mounted on the motion platform. For 2D US imaging, the overall system latency, including all delay times from the imaging and delivery chain, ranged from 392 to 424 ms depending on the lateral sector size. For 3D US imaging, the latency ranged from 566 to 1031 ms depending on the elevational sweep. The latency-corrected geometric root-mean squared error was below 0.75 mm (2D US) and below 1.75 mm (3D US). For the prostate SBRT delivery, the impact of a range of system latencies (400-1000 ms) on the MLC tracking performance was minimal in terms of gamma failure rate. Real-time MLC tracking based on a noninvasive US input is technologically feasible. Current system latencies are higher than those for x-ray imaging systems, but US can provide full volumetric image data and the impact of system latency was measured to be small for a prostate SBRT case when using a US-like motion input. 4. The impact of CBCT-imaging and verification time on prostate motion using 4D TPUS Clarity system Author(s): Pang P.P.E.; Boo H.S.A.; Loh M.Q.J.; Chan W.S.J.; Aryani S.N.; Tuan K.L.J.; Knight K.; Baird M. Source: Radiotherapy and Oncology; Apr 2016; vol. 119 Publication Type(s): Journal: Conference Abstract Abstract:Purpose or Objective: Accuracy of radiotherapy to the prostate is often challenged by geometrical uncertainties due to inherent organ motion attributed to daily variations of the bladder and rectal volumes and contents. This study aims to simulate the use of 4D Clarity ultrasound image guidance without CBCT imaging to analyse the magnitude and trend of prostate motion during treatment (74Gy given in 37 fractions). The impact of CBCT imaging and verification time on prostate motion will be analysed. Material and Methods: 175 intrafraction monitoring sessions from 5 patients who underwent radical prostate volumetric modulated arc therapy (VMAT) monitored using 4D transperineal ultrasound scan (TPUS) resulted in a total of 1461.2min of data (184,085 positioning points) being analysed. All patients were instructed to comply with a full bladder protocol (i.e. 300-450ml in 30-45min) without specific rectal preparation protocol. Mean prostate motion was calculated and analysed in relation to time in the subsequent fractions. Overall treatment time was defined from acquisition of CBCT to treatment beam off time and imaging time was defined from time of CBCT acquisition to first beam on. Imaging time was subtracted from the overall treatment time for analysis of prostate motion without CBCT for verification. The remaining duration was representative of treatment time using 4D Clarity ultrasound imagePurpose or Objective: Accuracy of radiotherapy to the prostate is often challenged by geometrical uncertainties due to inherent organ motion attributed to daily variations of the bladder and rectal volumes and contents. This study aims to simulate the use of 4D Clarity ultrasound image guidance without CBCT imaging to analyse the magnitude and trend of prostate motion during treatment (74Gy given in 37 fractions). The impact of CBCT imaging and verification time on prostate motion will be analysed. Material and Methods: 175 intrafraction monitoring sessions from 5 patients who underwent radical prostate volumetric modulated arc therapy (VMAT) monitored using 4D transperineal ultrasound scan (TPUS) resulted in a total of 1461.2min of data (184,085 positioning points) being analysed. All patients were instructed to comply with a full bladder protocol (i.e. 300-450ml in 30-45min) without specific rectal preparation protocol. Mean prostate motion was calculated and analysed in relation to time in the subsequent fractions. Overall treatment time was defined from acquisition of CBCT to treatment beam off time and imaging time was defined from time of CBCT acquisition to first beam on. Imaging time was subtracted from the overall treatment time for analysis of prostate motion without CBCT for verification. The remaining duration was representative of treatment time using 4D Clarity ultrasound image
منابع مشابه
Spotlight on measles 2010: ongoing measles outbreak in Greece, January-July 2010.
A measles outbreak (126 reported cases to date) has been ongoing in Greece, since January 2010, originally related to the recent outbreak in Bulgaria. Cases are mostly unvaccinated, and mainly belong to three groups: Roma population of Bulgarian nationality, Greek Roma population, and Greek non-minority population. In these population groups, 67%, 95%, and 25% of cases respectively were childre...
متن کاملFirst case of Echinococcus vogeli infection imported to the Netherlands, January 2013.
In January 2013 in the Netherlands, a man in his 50s from Suriname underwent hemihepatectomy because of a cystic liver mass, assumed to be a cystadenoma. Pathology revealed an echinococcal infection. PCR analysis of cyst material identified Echinococcus vogeli, causing polycystic hydatid disease. This echinococcus species is rarely diagnosed outside South America. The patient received adequate ...
متن کاملZika virus detection in urine from patients with Guillain-Barré syndrome on Martinique, January 2016.
We report two cases of Guillain-Barré syndrome who had concomitant Zika virus viruria. This viruria persisted for longer than 15 days after symptom onset. The cases occurred on Martinique in January 2016, at the beginning of the Zika virus outbreak. Awareness of this possible neurological complication of ZikV infection is needed.
متن کاملNecrotising fasciitis as atypical presentation of infection with emerging Neisseria meningitidis serogroup W (MenW) clonal complex 11, the Netherlands, March 2017
In March 2017, a patient with necrotising fasciitis caused by Neisseria meningitidis serogroup W (MenW) clonal complex 11 was diagnosed in the Netherlands. Unusual and severe presentations of MenW infections are common in the current European epidemic. In the Netherlands, the incidence of MenW infections increased 10-fold, from an average of 0.03 per 100,000 population in 2002-2014 to 0.29 in 2...
متن کاملStereotactic Radiosurgery and Stereotactic Body Radiotherapy
Professional Institutional Original Effective Date: October 17, 2006 Original Effective Date: May 1, 2007 Revision Date(s): January 20, 2007; April 1, 2007; September 25, 2007; June 26, 2008; January 1, 2009; June 30, 2009; February 25, 2011; January 15, 2013; March 27, 2014; January 21, 2016; December 20, 2017 Revision Date(s): September 25, 2007; June 26, 2008; January 1, 2009; June 30, 2009;...
متن کاملAwareness and use of the Rapid Palliative Radiotherapy Program by family physicians in Eastern Ontario: a survey
The Ottawa Rapid Palliative Radiotherapy Program (RPRP) was established in 1999 with the goal of facilitating access by family physicians to radiotherapy services for patients with advanced symptomatic cancer. Two years later, an audit revealed that of the 148 patients treated by the program, only 19 had been referred by family physicians.We therefore assessed awareness of the RPRP and percepti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017