Prevention of knot slippage with the use of cyanoacrylate glue: a mechanical study.

نویسندگان

  • George H Smith
  • J E McEachan
  • A McLean
  • J S Huntley
چکیده

PURPOSE To assess the effect of cyanoacrylate glue on knot slippage and strength in vitro. METHODS Ethibond 3/0 was tested using a tensile tester. A single drop of cyanoacrylate glue was applied to the knots. Seven knot configurations (10 samples each) were tested: (1) a surgeon's knot (S) plus 4 square throws (+4) without glue (control group), (2) S plus one square throw (+1) without glue, (3) S+1 with glue, (4) S with glue, (5) S+1 wet posttie without glue, (6) S+1 wet pre-tie without glue, and (7) S+1 wet pre-tie with glue. Wet sutures were immersed in normal saline for 24 hours prior to knot tying. Wet pre- and post-tie sutures were immersed for one minute prior to knot tying and tensile testing, respectively. Outcome measures were the mode of failure (knot slippage or suture snapping) and the ultimate tensile strength. RESULTS All knots without glue failed owing to knot slippage, except for the controls, whereas all knots with glue failed owing to suture snapping. The ultimate tensile strength was significantly higher in knots with glue and controls than in knots without glue. The ultimate tensile strength did not differ significantly between S+4 without glue and S with glue (p=0.48), indicating that glue could reinforce knots and reduce the number of throws needed. Wet suture is protective against failure (p<0.01). CONCLUSION Cyanocrylate glue may have clinical applications for flexor tendon repairs for which a reduced knot size is advantageous.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the use of silk sutures and cyanoacrylate tissue glue after periodontal flaps in patients with moderate periodontitis

Comparison of the use of silk sutures and cyanoacrylate tissue glue after periodontal flaps in patients with moderate periodontitis Dr. A. Mogharehabed* - Dr. SH. Mirmohammadi** *- Assistant Professor of Periodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Sciences. **- Dentist. Background and Aim: The use of silk suturing materials and cyanoacrylate tissue glue are common ...

متن کامل

The Application of a New Cyanoacrylate Glue in Pediatric Surgery for Fistula Closure

Surgical glues have been used in pediatric surgery because of the fragility of tissue, and to prevent major surgeries. The present report describes our experience with using a new cya-noacrylate Glubran 2 (Viareggio, Italy) in the treatment of five cases of tracheoesophageal atresia with fistula (one fistula protection, three recurrent fistula, and one unstable patients), two cases of hypospadi...

متن کامل

Comparison of silk sutures and 2–ethyl–cyanoacrylate on wound closure following surgical crown lengthening using apically positioned flap surgery

Comparison of silk sutures and 2–ethyl–cyanoacrylate on wound closure following surgical crown lengthening using apically positioned flap surgery Dr. A. Moghareh Abed* - Dr. M. E'tesampoor*** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Background and Aim: The use of cyanoacrylate tissue glue as an alternative to silk sutur...

متن کامل

Presentation and Analysis of Methods for Increasing Glue Joint Strength in the Same Length Joint

Glue joints are more useful in Aerospace so in this article we presented new method for glue joint. In this method the maximum stresses that occurs at the edges of the bottom glue joint and cause ultimate failure in this type of connection is Decrease and increase the glue joint strength. In this method glue in the area overlapping the discrete and separate column considered Also, the connectio...

متن کامل

Glubran2 surgical glue: in vitro evaluation of adhesive and mechanical properties.

BACKGROUND In surgical and endoscopic procedures, tissue adhesives are commonly used as reinforcement of sutures or as bonding and hemostatic agents. Fibrin glues do not guarantee adequate properties for many clinical applications; on the contrary, cyanoacrylate glues guarantee high bonding strength between biologic tissues. The aim of this study was to provide evidence regarding adhesive and s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2013