Diagnostic characterization of ablation plasma ion implantation

نویسندگان

  • B. Qi
  • R. M. Gilgenbach
  • M. C. Jones
  • M. D. Johnston
  • Y. Y. Lau
  • L. M. Wang
  • J. Lian
  • A. Lazarides
چکیده

Experiments are reported in which two configurations for ablation-plasma-ion-implantation ~APII! are characterized by diagnostics and compared. The first configuration oriented the target parallel to the deposition substrate. This orientation yielded ion-beam-assisted deposition of thin films. A delay (.5 ms) between laser and high voltage was necessary for this geometry to avoid arcing between negatively biased substrate and target. The second experimental configuration oriented the target perpendicular to the deposition substrate, reducing arcing, even for zero/negative delay between the laser and the high voltage pulse. This orientation also reduced neutral atom, ballistic deposition on the substrate resulting in a pure ion implantation mode. Ion density measurements were made by resonant laser diagnostics and Langmuir probes, yielding total ion populations in the range of 10. Implanted ion doses were estimated by electrical diagnostics, and materials analysis, including x-ray energy dispersive spectroscopy and x-ray photoelectron spectroscopy, yielding implanted doses in the range 10 ions/cm per pulse. This yields an APII efficiency of order 10% for implantation of laser ablated ions. Scaling of ion dose with voltage agrees well with a theory assuming the Child– Langmuir law and that the ion current at the sheath edge is due to the uncovering of the ions by the movement of the sheath. Thin film analysis showed excellent adhesion with smoother films for an accelerating voltage of 23.2 kV; higher voltages (27.7 kV) roughened the film. © 2003 American Institute of Physics. @DOI: 10.1063/1.1565822#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of Expanding Laser Plasma Produced by Laser Ablation

This work is devoted to characterizing the plasma produced by nanosecond laser ablation. The expanding plasma was generated by the interaction of a home made XeCl excimer laser with a Cu target. The time-of-flight method was utilized as diagnostic tool of the plasma charged particles. By this method, in fact, we were able to measure the ion and electron currents, the charge-states and the energ...

متن کامل

Coating Deposition Using Vacuum Arc and Ablation Metal Plasma

An innovative concept in the development of advanced coating deposition and ion implantation method including an application of filtered DC metal plasma or ablation plasma and highfrequency short-pulsed negative bias voltage with a duty factor in the range 10–99% are considered. It was shown that plasma based ion implantation as well as ion-assisted coating deposition may be realized for metal ...

متن کامل

Extraction of ions from the matrix sheath in ablation-plasma ion implantation

A simple one-dimensional theory is presented to assess the implantation of ions from the ion matrix sheath ~IMS! in an ablated plasma plume that is approaching a negatively biased substrate. Under the assumption that the plume geometry, the electron and ion density distributions, and the potential distribution are frozen during the IMS extraction, the implanted ion current is calculated as a fu...

متن کامل

Influence of nitrogen ion implantation on the nanostructure and corrosivity of Ni/stainless steel substrates

Ion implantation is a surface modification technology to produce new material on the surface by impingement of high energy ions from the ion accelerator. In this work, AISI 304 stainless steels were coated with 90 nm Ni film by electron beam deposition and implanted by a flow of 5×1017 N cm−2 at 400 K temperature with different implantation energies of 10, 20, 30 and 40 keV. The prepared sample...

متن کامل

Theoretical Treatment of Krypton Ion Beam Bombardement in Zinc Target

The manuscript reports a study of Kr ion implantation in a Zn target in the 10-50 keV energy range at different source parameters, which combines experimental data and simulation with the SRIM package. The implanted thickness for the 45 keV was found to be 10 μm. The ion penetration depths for different films at different energies (10-50 keV) were calculated using SRIM computer program and foun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003