A Comparative Study on Contamination Deposited Characteristics of ±800kV DC Line Insulators

نویسندگان

  • Fangcheng Lv
  • Chunxu Qin
  • Yunpeng Liu
  • Wenyi Guo
  • Ruihai Li
چکیده

This report describes the natural contamination test results of ±800kV line insulators at high altitudes. Natural exposure tests with -816kV DC voltage energization were carried out at National Engineering Laboratory for UHV Engineering Technology (Kunming).The results showed that the strain type and V-type insulator strings show a lighter pollution and the insulators with a better aerodynamic shed shape show a better contamination deposited characteristic. Also the ratios of contamination on top surface to that on bottom surface in terms of the equivalent salt deposit density (ESDD) and the nonsoluble deposit density (NSDD) were influenced by the insulator shed shapes and the string types. The ESDD and the NSDD along the insulator strings presented decreasing trend from the earth side to the line side.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Pollution Location on Time and Frequency Characteristics of Leakage Current of Porcelain Insulator String under Different Humidity and Contamination Severity

One of the important factors influencing outdoor insulators performance is pollution phenomenon. The pollution, especially during humidity condition, reduces superficial resistance of insulator and lead to a flow of Leakage Currents (LC) on the insulator surface, which may result in total flashover. The LC characteristics are affected by parameters such as nature and severity of pollution. Loca...

متن کامل

A new procedure for determination of insulators contamination in electrical distribution networks

This paper presents a novel method for determination of insulator contamination (IC) level. ICs caused some problems in electric networks. Some faults occur in electric system due to ICs. These faults sometimes log to a sudden and serious damages to the systems. So ICs reduce power quality and reliability indexes. Usually insulator washing is a solution for this problem and its events. Insulato...

متن کامل

Natural Contamination and Surface Flashover on Silicone Rubber Surface under Haze–Fog Environment

Anti-pollution flashover of insulator is important for power systems. In recent years, haze-fog weather occurs frequently, which makes discharge occurs easily on the insulator surface and accelerates insulation aging of insulator. In order to study the influence of haze-fog on the surface discharge of room temperature vulcanized silicone rubber, an artificial haze-fog lab was established. Based...

متن کامل

A comparative Monte Carlo study on 6MV photon beam characteristics of Varian 21EX and Elekta SL-25 linacs

Background: Monte Carlo method (MC) has played an important role in design and optimization of medical linacs head and beam modeling. The purpose of this study was to compare photon beam features of two commercial linacs, Varian 21EX and Elekta SL-25 using MCNP4C MC code. Materials and Methods: The 6MV photon beams of Varian 21EX and Elekta Sl-25 linacs were simulated based on manufacturers pro...

متن کامل

A Comparative Study of Insulators on Magnetic Properties of Sendust Based Nanocomposite Powder Cores

In this study, Sendust (Fe85Si9.6Al5.4) nanostructure alloy was prepared bymechanical alloying and was characterized by X-ray diffraction. In addition, the alloy’smorphology and its distribution particle size were investigated by scanning electronmicroscopy method. The alloyed powders were insulated with 4wt% of three differentinsulating materials including polyvinyl alc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013